G9SA-321-T30-AC100240 Sti (Scientific Technologies, Inc.), G9SA-321-T30-AC100240 Datasheet - Page 3

no-image

G9SA-321-T30-AC100240

Manufacturer Part Number
G9SA-321-T30-AC100240
Description
Relay, Safety Monitoring, 100-240VAC, 3NO Immediate, 2NO Delayed, 30sec
Manufacturer
Sti (Scientific Technologies, Inc.)
Datasheet

Specifications of G9SA-321-T30-AC100240

Brand/series
G9SA Series
Lead Free Status / Rohs Status
RoHS Compliant part
Specifications
Ratings
Power Input
Note: When an Expansion Unit is connected, the power consumption is increased by 2 VA/2 W max.
Inputs
Note: When an Expansion Unit is connected, the input current is increased by 30 mA max.
Contacts
Characteristics
Note: 1. The contact resistance was measured with 1 A at 5 VDC using the voltage-drop method.
D-50
Power supply voltage
Operating voltage range
Power consumption
(See note.)
Input current (See note.)
Rated load
Rated carry current
Item
Contact resistance (see note 1)
Operating time
Response time (see note 2)
Insulation resistance (see note 3)
Dielectric
strength
Vibration resistance
Shock
resistance
Durability
Minimum permissible load (reference value)
Ambient temperature
Ambient humidity
Terminal tightening torque
Weight (see note 4)
Approved standards
EMC
2. The response time is the time it takes for the main contact to open after the input is turned OFF.
3. The insulation resistance was measured with 500 VDC at the same places that the dielectric strength was checked.
4. Weight shown is for 24-VAC/VDC type. For 100 to 240-VAC type, add approximately 20 g.
Item
Item
Item
Between different outputs
Between inputs and outputs
Between power inputs and outputs
Between power inputs and other inputs
(only for 100 to 240-V models)
Destruction
Malfunction
Mechanical
Electrical
Resistive load (cos f =1)
250 VAC, 5 A
40 mA max.
5 A
G9SA-301/501/321-T#/TH301/EX301/EX031-T#
24 VAC/VDC:24 VAC, 50/60 Hz, or 24 VDC
100 to 240 VAC:100 to 240 VAC, 50/60 Hz
85% to 110% of rated power supply voltage
24 VAC/VDC: 1.8 VA/1.7 W max.
100 to 240 VAC: 9 VA max.
G9SA-301/321-T#/TH301
G9SA-301/TH301
100 mW
30 ms max. (not including bounce time)
10 ms max. (not including bounce time)
100 MW min. (at 500 VDC)
2,500 VAC, 50/60 Hz for 1 min
10 to 55 Hz, 0.75-mm double amplitude
300 m/s
100 m/s
5,000,000 operations min. (at approx. 7,200 operations/hr)
100,000 operations min. (at approx. 1,800 operations/hr)
5 VDC, 1 mA
Operating:-25°C to 55°C (with no icing or condensation)
Storage:-25°C to 85°C (with no icing or condensation)
Operating:35% to 85%
Storage:35% to 85%
0.98 N·m
Approx. 210 g
EN954-1, EN60204-1, EN574 (-TH301), UL508, CSA C22.2 No. 14
EMI: EN55011 group 1 class A
EMS: EN50082-2 group 1
G9SA-301/TH301
60 mA max.
2
2
24 VAC/VDC: 2.8 VA/2.6 W max.
100 to 240 VAC: 11 VA max.
G9SA-501
G9SA-501
Approx. 270 g
G9SA-501/321-T#
Safety Sensors / Components
24 VAC/VDC: 3.5 VA/3.3 W max.
100 to 240 VAC: 12.5 VA max.
Approx. 130 g
G9SA-EX301/EX031-T#
G9SA-321-T#

Related parts for G9SA-321-T30-AC100240