PIN CONFIGURATIONS
Note: Bottom ground plate must be grounded for proper RF performance.
SERIAL DATA LOAD
Serial data is shifted into the register on the rising edge of clock, MSB first. The OE rising edge must occur prior to any
additional rising clock edges. See the Electrical Spec Table for AC parameters.
TRUTH TABLE
Operation: Data on serial input D is clocked into internal registers on the low to high transition of the Clock signal (CK).
The register output is enabled when Output Enable (OE) is in the low state. "0" = CMOS Low, "1" = CMOS High.
www.honeywell.com/microwave
Pin
1
2
3
4
5
6
7
8
S5
0
0
0
0
0
0
1
1
Function
RF INPUT
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
V
DD
S4
0
0
0
0
0
1
0
1
Pin
10
11
12
13
14
15
16
9
RF OUTPUT
Function
GROUND
GROUND
GROUND
S3
DATA
0
0
0
0
1
0
0
1
CLK
V
OE
SS
S2
0
0
0
1
0
0
0
1
S1
0
0
1
0
0
0
0
1
S0
0
1
0
0
0
0
0
1
Reference Input
31.5 dB
Output
0.5 dB
16 dB
1 dB
2 dB
4 dB
8 dB
3