289G Hammond Manufacturing, 289G Datasheet - Page 3

Transformers 1500VA ISOLATION

289G

Manufacturer Part Number
289G
Description
Transformers 1500VA ISOLATION
Manufacturer
Hammond Manufacturing
Type
Power Transformersr
Datasheet

Specifications of 289G

Power Rating
1500 VA
Primary Voltage Rating
230 V
Dimensions
215.9 mm L x 228.6 mm W x 171.5 mm H
Product
Isolation Transformers
Height
171.5 mm
Length
215.9 mm
Number Of Outputs
1
Termination Style
Plug In
Width
228.6 mm
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Straight Isolation
through careful design, but these units are NOT usable in an office environment.
AC regulating - protects against both brownouts & over voltage conditions.
Protects against any power problem other than a blackout.
Will operate through a 3 millisecond (minimum) blackout.
Long life - ferroresonant design - no moving parts.
Ferroresonant design also filters out surges, line harmonics, and RF noise.
Input 120VAC (+10 % to -25 %), 60 Hz
Output 120VAC (+/- 3 %).
Provides circuit isolation.
Noise Isolation (RF) of 120 db common mode, 60 db normal mode.
Spike attenuation: 250:1 minimum.
Sine wave output - total harmonic distortion (THD): 3 %
Units also include a 2nd stage of high frequency filtering on the output - a Hammond Mfg. exclusive.
Operating temperature range of -40 degrees C to +40 degrees C.
Standard 3-wire, grounded plug & receptacle.
Front panel lighted power switch.
Input (primary) connected to an extra long 15 foot, heavy duty 14/3 SJTW cord for extreme temperature ranges.
Integral molded, standard North American plug (NEMA 5-15P).
Output (secondary) connected to a rear mounted, standard North American, grounded receptacle (NEMA 5-15R) -
quantity depends on power capacity of unit (see table below).
Rugged two piece ventilated steel enclosure.
Finished in a grey/beige color, textured powder paint with rubber feet installed.
NOTE 1: Due to the nature of ferroresonant designs - these units do produce audible noise. We have reduced this
NOTE 2: These units provide complete isolation from the source voltage. In other words, the "neutral" output wire has
no connection to ground, this is a UL requirement for this type of device. Therefore plug-in circuit testers
& line "polarity" testing devices will NOT function on the output as it is completely isolated.
North American Mark of Safety: C UL & UL listed (File #E211544).
©
St. Laurent, Quebec (514) 343-9010
Cheektowaga, NY (716) 630-7030
Guelph, Ontario (519) 822-2960
CANADA
USA
CV1201200
CV1201800
CV120300
CV120600
Part No.
- Constant Voltage - Plug In (CV Series)
1200
1800
300
600
VA
Capacity
(RMS)
Amps
A.C. Regulator - Plug In
www.hammondmfg.com
2.5
10
15
5
(120 V to 120V)
Constant Voltage
Rear Outlets
Number of
2
4
4
6
60
Height
12.00
7.00
9.00
9.00
Dimensions (Inches)
Width
10.13
10.13
12.13
7.13
Depth
12.30
19.50
19.50
20.50
Queenstown, Australia 61-8-8240-2244
Basingstoke, UK 01256 812812
Lbs.
25.3
Wt.
48
74
95
AUSTRALIA
EUROPE

Related parts for 289G