S3K2U1440-5 SOLA HEVI DUTY, S3K2U1440-5 Datasheet - Page 24

UPS - Uninterruptible Power Supplies 1440VA/1080W 230V

S3K2U1440-5

Manufacturer Part Number
S3K2U1440-5
Description
UPS - Uninterruptible Power Supplies 1440VA/1080W 230V
Manufacturer
SOLA HEVI DUTY
Datasheet

Specifications of S3K2U1440-5

Power Rating
1440 VA
Output Voltage Rating
230 V
Number Of Outlets
8
Interface Port
USB / SNMP
Runtime (full Load)
11 min
Runtime (half Load)
26 min
Topology
Line Interactive
Tower / Rackmount
Tower / Rackmount
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
6.0
6.1
6.2
C
ON/Alarm Silence/Battery Test Button
This button controls output power to connected load(s) and has three functions:
ON—When the UPS is Off, pressing the ON/Alarm Silence/Battery Test button for more than one
(1) second will start the UPS, and an audible alarm sounds briefly. The UPS is capable of starting on
battery (battery start).
Alarm Silence—When a UPS audible alarm is active, pressing and releasing the ON/Alarm Silence/
Battery Test button will silence the active audible alarm, whether mains power is present or not.
Once the alarm silence function has been activated, all active audible alarms will remain silenced
until a new alarm condition is detected.
Battery Test—To initiate a manual battery test, press the ON/Alarm Silence/Battery Test button for
at least one second while operating from mains power with no alarm conditions present.
OFF Button
• If all five (5) Battery indicators are not illuminated, allow the UPS to recharge the batteries for
• After 24 hours, retest the batteries.
• After the batteries have been retested, if all five (5) Battery indicators are not illuminated, con-
ONTROLS AND
24 hours.
tact your local distributor, Sola/Hevi-Duty representative or Sola/Hevi-Duty Technical Services.
NOTE
The LOW BATTERY, OVER TEMP and OVERLOAD warning
audible alarms CANNOT be silenced.
•On
•Alarm Silence
•Battery Test
When the UPS is on (in either Normal or Battery mode), pressing the OFF button
for more than one (1) second will shut down the UPS. An audible alarm sounds
briefly.
I
NDICATORS
All indicators illuminated
for illustrative purposes only.
18
Controls and Indicators