ACD-3300 IND Amprobe, ACD-3300 IND Datasheet - Page 2

Clamp Multimeters & Accessories AC 1000A INDUSTRIAL CLAMP

ACD-3300 IND

Manufacturer Part Number
ACD-3300 IND
Description
Clamp Multimeters & Accessories AC 1000A INDUSTRIAL CLAMP
Manufacturer
Amprobe
Datasheet

Specifications of ACD-3300 IND

Ranging
Auto
Frequency
40 Hz to 20 KHz
Maximum Ac Current
1000 A
True Rms
Yes
Voltage
750 VAC, 1000 VDC
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
3434877
ACD-3300 IND CAT IV Industrial True RMS Clamp Meter
Specifications
DC Volts
AC Volts True RMS
Peak Hold
AC coupled TRMS
AC Current True RMS
Resistance
Capacitance
Amprobe® Test Tools
Input impedance
Overload protection
Crest factor
Input impedance
Overload protection
Peak Hold
AC coupled TRMS
Crest factor
Overload protection
Open circuit volts
Overload protection
Overload protection
(valid for 23 °C ± 5 °C, for less than 75% relative humidity).
Ranges
660.0 mV, 6.600 V, 66.00 V, 660.0 V, 1000 V
660 mV: >100 MΩ; 6.6 V:10 MΩ; 66 V to 1000 V: 9.1 MΩ
1000 VDC or 750 VAC rms
Ranges
660.0 mV
6.600V, 66.00V
660.0V, 750V
Frequency*
* Frequency: 10% to 100% of voltage range
Ranges
66.00V, 660.0V, 750V
5% to 100% of range
≤ 3
660 mV: >100 MΩ; 6.6 V:10 MΩ; 66 V to 750 V: 9.1 MΩ
1000 VDC or 750 VAC rms
Ranges
66.00A
66.00A
660.0A
660.0A
1000 A
1000 A
Frequency*
Ranges
66.00A, 660.0A, 1000A
* Frequency: 10% to 100% of current range
5% to 100% of range
≤ 3
1000A AC
Range
660.0Ω, 6.600kΩ, 66.00kΩ, 660.0kΩ
6.600MΩ
66.00MΩ
-0.8 Vdc typical , (-1.2 Vdc on 660 Ω range)
1000 VDC or 750 VAC rms
Range
6.600ηF, 66.00ηF
660.0ηF, 6.600μF, 66.00μF,660.0μF
6.6 mF
1000 VDC or 750 VAC rms
Frequency
50 to 100 Hz
50 to 500 Hz
50 to 500 Hz
50 to 1 kHz
Frequency
50 to 500 Hz
Frequency
50 to 60 Hz
61 to 400 Hz
50 to 60 Hz
61 to 400 Hz
50 to 60 Hz
61 to 400 Hz
50 to 1kHz
Frequency
50 to 400 Hz
Accuracy
± (1.5% rdg + 8 dgts)
± (1.5% rdg + 8 dgts)
± (1.5% rdg + 8 dgts)
± (0.1% rdg + 5 dgts)
Accuracy
± (3.0% rdg + 300 dgts)
Accuracy
± (2.0% rdg + 10 dgts)
± (3.0% rdg + 10 dgts)
± (2.0% rdg + 10 dgts)
± (3.0% rdg + 10 dgts)
± (2.5% rdg + 10 dgts)
± (3.5% rdg + 10 dgts)
± (0.1% rdg + 5 dgts)
Accuracy
± (3.0% rdg + 200 dgts)
Accuracy
± (1.0% rdg + 5 dgts)
± (2.0% rdg + 5 dgts)
± (3.5% rdg + 5 dgts)
Accuracy
±(3.0% rdg + 20 dgts)
±(3.0% rdg + 10 dgts)
±(5.0% rdg + 10 dgts)
Accuracy
± (0.5% rdg + 2 dgts)
Data Sheet