6510 Protek, 6510 Datasheet

Benchtop Oscilloscopes 100 MHz 2Ch. Dual Ti

6510

Manufacturer Part Number
6510
Description
Benchtop Oscilloscopes 100 MHz 2Ch. Dual Ti
Manufacturer
Protek
Datasheet

Specifications of 6510

Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
651001/MA
Manufacturer:
ATMEL
Quantity:
6 218
Part Number:
651005136521 ,
Manufacturer:
WURTH
Quantity:
12 000
Part Number:
65100516121
Manufacturer:
WE
Quantity:
12 000
Part Number:
651026
Manufacturer:
KET
Quantity:
53 465
Part Number:
651032-5
Quantity:
53 466
2
Protek Test & Measurement
40 Boroline Road, Allendale, NJ 07401 Tel: 201-760-9898 Fax: 201-760-9888
Website: www.protektest.com E-Mail: sales@protektest.com
Vertical Amplifier
(CH 1 and CH 2)
Sensitivity:
1mV/Div to 1 V/Div)
Accuracy:
Bandwidth (-3dB):
Rise Time:
Input Impedance:
Input Coupling:
Invert Channel:
Display Modes:
Maximum Input Voltage:
CH1 Signal Output:
Horizontal Sweep
Timebase A
steps (1-2-5)
Accuracy:
Hold Off:
Timebase B
Sweep Time:
Accuracy:
Delay Time:
Delay Modes:
Sweep Displays:
S P E C I F I C A T I O N S
6510
Continuously adjustable to > 2X sweep time
±3% (± 5% in X10 Mag)
±3%
±3% (±5% in X5 Mag)
5 mV/Div to 5 V/Div in 7 calibrated steps, (X5 Mag
Sweep Time:
Continuously variable from 0.2µs to 2s
X10 Mag:
50ns/Div to 10µs/Div in 8 steps (1-2-5)
3.5 ns, X5 Mag: 20MHz Bandwidth:
Continuous or triggered
CH2
AC-Gnd-DC
CH1, CH2, Add, Subtract, Dual (Alt/Chop)
A, B, A alt B, B triggered, X-Y
1MΩ + 25 pF
DC to 100MHz
20mV into 50Ω
5ns/Div to 20ms/Div
400V (DC or AC peak)
50ns/Div to 0.2 s/Div in 21 calibrated
Four traces may be simultaneously displayed in ALT-sweep
Five vertical display modes: CH1, CH2, Dual, Add, Subtract
Vertical mode triggering for displaying 2 unrelated signals
Trigger hold-off circuit for synchronizing complex waveforms
Sweep speeds to 2nS/Div
12kV acceleration voltage for bright displays of low duty cycle signals
Z axis input
TV Synchronization for either line or field patterns
20MHz bandwidth limit switch for triggering signals in a noisy environment
Dual Trace, Dual Timebase, 100MHz Oscilloscope
17 ns
X-Y Mode
CH1-X axis, CH2-Y axis Sensitivity:
amplifier
Bandwidth (X-axis):
Phase Error:
Triggering
Trigger Modes:
Source:
Coupling:
Slope:
Trigger Sensitivity:
100MHz: 1.5 Div.
Ext.: DC to 10MHz: 200mV; 10MHz to 100MHz: 500mV
TV: Int.:1 Div Min; Ext: 1V P-P
External Trigger Input:
Maximum Input Volts: 400V DC or AC peak
Z Axis Modulation
Sensitivity:
voltage input
Bandwidth (-3dB):
Input Impedance:
Calibrator Signal
Voltage:
Duty Cycle:
CRT
Type:
Acceleration Voltage:
6" rectangular CRT with internal graticule. (1 Div = 1cm)
Positive or negative
Int. CH2, line ext.
0.5V ±3% P-P 1kHz Square Wave
AC
±5V P-P Intensity increases with a negative going
Approx. 50%
3° DC to 10kHz
Auto, Normal, TV-V, TV-L
≈ 2 KΩ
DC to 2MHz
Int: DC to 10MHz: 0.5 Div10MHz to
DC to 2MHz
12 kV
Impedance 1MΩ + 20 pF
6510
Same as CH1 vertical
General Specifications
Power Requirements:
240V selectable
Frequency:
Power Consumption:
Operating Temperature:
humidity
Dimensions:
Weight:
Supplied Accessories:
Probes
24 lbs.
50/60Hz
5.3" H × 12.7"W × 14.5" D
55W
AC Input Voltage: 100V, 120V, 220V,
Manual, 1 AC Power cord, (2) X10
0 to 40°C at 35% to 85% relative
CE