1140-G151-P7M1-7A E-T-A Circuit Protection and Control, 1140-G151-P7M1-7A Datasheet

no-image

1140-G151-P7M1-7A

Manufacturer Part Number
1140-G151-P7M1-7A
Description
Circuit Breaker; Therm; Push; Cur-Rtg 7A; Panel; 2 Pole; Vol-Rtg 240/48VAC/VDC
Manufacturer
E-T-A Circuit Protection and Control
Type
Thermalr
Datasheet

Specifications of 1140-G151-P7M1-7A

Actuator Type
Push
Brand/series
1140 Series
Characteristic
Medium Delay
Current, Rating
7 A
Dimensions
0.748"Lx0.433"Wx1.95"H
Mounting Hole Size
0.35x0.378 "
Mounting Type
Panel
Number Of Poles
2
Termination
Blade
Voltage, Rating
240/48 VAC/VDC
Type: 1140-G.5
Dimensions
Internal connection diagrams
Miniaturised double pole thermal circuit breaker with push-to-reset
tease-free, trip-free, snap action mechanism (R-type TO CBE to EN
60934). Threadneck panel mounting. Suitable for line and neutral
switching - the thermal actuator operating on one pole simultaneously
opens both poles under overload conditions.
Approved to CBE standard EN 60934 (IEC 60934).
Voltage rating:
Current ratings:
from 0.05 A to 16 A
Number of poles:
double pole
Mounting method:
threadneck
Terminal design:
blade terminals
Actuation:
push button
Auxiliary contacts:
without auxiliary contacts
Water splash protection:
with water splash protection
without water splash protection
Illumination:
without illumination
Typical life:
0.05...3 A: 3,000 operations at 2 x I
3.5...8 A: 1,000 operations at 2 x I
10...16 A: 100 operations at 2 x I
Interrupting capacity I
0.05...3 A: 6 x I
3.5...8 A: 8 x I
10...16 A: 120 A
Approvals:
VDE, CSA, UL, Kema
AC 240 V
DC 48 V
UL/CSA: AC 250 V
UL/CSA: DC 50 V
N
N
cn
:
N
N
, inductive
N
, resistive
, resistive

Related parts for 1140-G151-P7M1-7A

1140-G151-P7M1-7A Summary of contents

Page 1

... Type: 1140-G.5 Dimensions Internal connection diagrams Miniaturised double pole thermal circuit breaker with push-to-reset tease-free, trip-free, snap action mechanism (R-type TO CBE to EN 60934). Threadneck panel mounting. Suitable for line and neutral switching - the thermal actuator operating on one pole simultaneously opens both poles under overload conditions. ...

Page 2

... Terminal design P7 blade terminals DIN 46244-C (QC 2x.110) Characteristic curve M1 medium delay Current ratings 0,05...16 A 1140 - ordering example *mounting hardware bulk shipped Standard current ratings and typical internal resistance values Current Internal Current rating (A) resistance (Ω) rating (A) ...

Page 3

... Thermal Overcurrent Circuit Breaker 1140-... (2-pole) Dimensions 1140-G15... tightening torque max. 0 -27 UNS-2A 1 blade terminal DIN 46244-A6.3-0.8 (QC .110 .551 9 .354 19 .748 Installation drawing operating area mounting area Accessories Water splash cover/knurled nut assembly, transparent X 201 285 01 (IP64 Internal connection diagram ø4.2 .165 Typical time/current characteristics at +23 ° ...

Related keywords