RKMWV 3-224/2 M LUMBERG AUTOMATION, RKMWV 3-224/2 M Datasheet - Page 2

no-image

RKMWV 3-224/2 M

Manufacturer Part Number
RKMWV 3-224/2 M
Description
LEAD,PUR, M8 R/A SKT-FREE END,3P,2M
Manufacturer
LUMBERG AUTOMATION
Datasheet

Specifications of RKMWV 3-224/2 M

Voltage Rating
60V
Current Rating
4A
Cable Assembly Type
Circular
Cable Length - Metric
2m
Jacket Colour
Black
Rohs Compliant
Yes
Connector Type A
Socket
Connector Type B
Free End
No. Of Poles
3
Technische Daten
Umgebungstemperatur
Werkstoffe
Gehäuse / Griffkörper
Kontaktträger
Kontakt
Gewindebuchse / Rändel-
schraube/-mutter / Sechskant-
schraube/-mutter / Hülse
O-Ring
Mechanische Daten
Schutzart
Elektrische Daten
Durchgangswiderstand
Nennstrom bei 40°C
Nennspannung
Bemessungsspannung
Prüfspannung
Isolationswiderstand
Verschmutzungsgrad
Bestellbezeichnung
Designation
RKMV 3-06/... M
RKMV 3-224/... M
RKMV 4-07/... M
RKMV 4-225/... M
RKMV 8-354/... M
Standardlängen: 2 M / 5 M / 10 M
Andere Kabellängen oder Leitungsaufbauten auf Anfrage.
Ein Einsatz der Produkte in aggressiven Medien
ist im Einzelfall zu überprüfen.
-40°C / +90°C
TPU
PA / TPU
CuZn, unternickelt und 0,8 µm
vergoldet
CuZn, vernickelt
FKM
IP 67/IP 69K
Nur im verschraubten Zustand
mit den dazugehörigen Gegen-
stücken.
≤ 5 mΩ
3- bis 4-polig 4 A
8-polig 1 A
3-polig 60 V
4- bis 8-polig 30 V
3-polig 63 V
4- bis 8-polig 36 V
3-polig 1,5 kV eff. / 60 s
4- bis 8-polig 0,8 kV eff. / 60 s
> 10
3
RKMWV 3-06/... M
RKMWV 3-224/... M
RKMWV 4-07/... M
RKMWV 4-225/... M
9
Cordsets, single-ended, for actuators, sensors and distribution boxes
Anschlussleitungen für Aktoren, Sensoren und Verteiler
Technical data
Operating temperature range -40°C / +90°C
Materials
Housing / Molded body
Insert
Contact
Receptacle shell / knurled screw/
nut / hexagon screw/nut / sleeve
O-ring
Mechanical data
Degree of protection
Electrical data
Contact resistance
Nominal current at 40°C
Nominal voltage
Rated voltage
Test voltage
Insulation resistance
Pollution degree
The application of these products in harsh environ-
ments should always be checked before use.
Polzahl
Poles
3
4
8
Standard lengths: 2 M / 5 M / 10 M
Other cable lengths or cable specifications on request.
Mantel
Outer jacket
PVC
PUR
halogenfrei / halogen free
PVC
PUR
halogenfrei / halogen free
PUR
halogenfrei / halogen free
TPU
PA / TPU
CuZn, pre-nickeled and
0.8 microns gold-plated
CuZn, nickel-plated
FKM
IP 67/IP 69K
Only in locked position with
its proper counterparts.
≤ 5 mΩ
3–4 poles 4 A
8 poles 1 A
3 poles 60 V
4–8 poles 30 V
3 poles 63 V
4–8 poles 36 V
3 poles 1.5 kV eff. / 60 s
4–8 poles 0.8 kV eff. / 60 s
> 10
3
9
www.lumberg-automation.com
10/2008

Related parts for RKMWV 3-224/2 M