6.716.010.000 KÜBLER, 6.716.010.000 Datasheet - Page 2

COUNTER, PRESET, 90-260VAC, 716

6.716.010.000

Manufacturer Part Number
6.716.010.000
Description
COUNTER, PRESET, 90-260VAC, 716
Manufacturer
KÜBLER
Datasheet

Specifications of 6.716.010.000

No. Of Digits / Alpha
6
Digit Height
8mm
Supply Voltage Range
90VAC To 250VAC
Power Consumption
5VA
Operating Temperature Range
-10°C To +50°C
Svhc
No SVHC (15-Dec-2010)
Count Speed Max
20kHz
Preset counter electronical
The follow modes can be programmed
C C o o n n n n e e c c t t i i o o n n d d i i a a g g r r a a m m : :
3/2005
P P r r o o g g r r a a m m m m i i n n g g
P P r r o o g g r r a a m m m m a a b b l l e e a a r r e e : :
I I n n p p u u t t p p o o l l a a r r i i t t y y : :
P P u u l l s s e e o o r r t t i i m m e e c c o o u u n n t t i i n n g g m m o o d d e e s s : :
I I n n p p u u t t t t y y p p e e s s i i n n p p u u l l s s e e c c o o u u n n t t e e r r m m o o d d e e : :
Pin connection X3:
PIN No.
1
2
3
4
5
Pin connection X2:
P P i i n n
1
2
3
4
5
6
7
1. Pulse counter
2. Frequency meter
3. Time meter
The counters 716/717 are programmed by means of the 4 front
keys. The operator guidance on this display allows a simple and
intuitive programming. All settings can be carried out by
selecting the corresponding parameters in this menu.
Positive (pnp) or negative (npn). The selection is valid for all
inputs
– adding with counting; start at 0
– subtracting with counting start at the preset (716)
– adding with automatic reset when the preset (716) or
– subtracting with automatic positioning at the preset (716) or
Cnt.Dir
uP.dn
and at preselection 2 (717)
the preset 2 (717)
preset 2 (717) when 0 is reached
d d e e s s c c r r i i p p t t i i o o n n
+24 V DC
0 V DC (GND) GND
INP A
INP B
Reset
Gate
Key
1 counting input
1 counting direction input
Differential counting
RS232
GND
RxD
TxD
RTS
CTS
1 adding input
1 subtracting input
Only for optional serial
interface
A A C C v v e e r r s s i i o o n n
Power supply
Count input A
Count input B
Reset input
Gate input
input for key lock
RS 422
RI+
RI-
DO+
DO-
RS 485
DO/RI+
DO/RI-
D D C C - - V V e e r r s s i i o o n n
n.c.
n.c.
D D e e c c i i m m a a l l p p l l a a c c e e : :
F F a a c c t t o o r r
O O u u t t p p u u t t s s i i g g n n a a l l
M M a a x x i i m m u u m m c c o o u u n n t t i i n n g g f f r r e e q q u u e e n n c c y y
T T i i m m e e r r
Pin connection X1:
P P i i n n
1
2
3
4
5
6
7
quad
quad2
Data can be displayed with with one, two or three decimal
point
For an optimum matching of the measuring signal, the displayed
values can be weighted by a scale factor between 0.0001 and
99.9999.
The function of the output signal can be preselected (independ-
ently for both outputs of model 717) as a normally-closed, nor-
mally open or a negative pulse signal.
The maximum counting frequency can be set to 30 Hz or 20 kHz.
Counting can be carried out in h, min, s or in h:min:s. The num-
ber of decimal places determines the resolution. A resolution
up to the ms-range can be achieved.
A A C C v v e e r r s s i i o o n n
Output1 Relay
Collector at Optocoupler output
Output 1 Relay
Emitter at Optocoupler output
Output 2
Relay common contact (C)
Emitter at optocoupler output
Output 2 Relay
closing contact (NO)
Output 2 Relay opening contact (NC)
Collector at Optocoupler-output
Power supply
90 ... 250 V AC
90 ... 250 V AC
Phase discriminator
to connect encoders with 2 signals shifted by 90°
Phase discriminator
with double pulse processing, to connect pulse
sources with 2 signals shifted by 90°
Für die die Zähler mit serieller Schnittstelle
ist optional eine Steuersoftware lieferbar.
Damit können die Zähler einfach über
einen PC programmiert werden. Im
Monitorprogramm werden die Messwerte
online angezeigt. Weiter Informationen
über die Software EzControl erhalten Sie
auf Seite 185.
D D C C v v e e r r s s i i o o n n
10 ... 30 V DC
0 V DC (GND)
www.kuebler.com
123