TES 5-4822WI TRACOPOWER, TES 5-4822WI Datasheet - Page 2

DC/DC CONVERTER, 12V, 5W

TES 5-4822WI

Manufacturer Part Number
TES 5-4822WI
Description
DC/DC CONVERTER, 12V, 5W
Manufacturer
TRACOPOWER
Datasheet

Specifications of TES 5-4822WI

Dc / Dc Converter O/p Type
Fixed
No. Of Outputs
2
Input Voltage
18V To 75V
Power Rating
5W
Output Voltage
12V
Output Current
210mA
Output Voltage 2
-12V
Output Current 2
-210mA
Rohs Compliant
Yes
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Input Specifications
Input current (full load)
Input current (no load)
Start-up voltage / under voltage shut down
Surge voltage (1 sec. max.)
Reverse voltage protection
Reflected input ripple current
Input filter
Output Specifications
Voltage set accuracy
Regulation
Minimum load
Temperature coefficient
Ripple and noise
Dynamic load response (25% load change)
Transient response (25% load step change)
Current limitation
Short circuit protection
Capacitive load
Remote On/Off
General Specifications
Temperature ranges
Humidity (non condensing)
Reliability, calculated MTTF (MIL-HDBK-217F, @+25°C, ground benign)
Isolation voltage (60 sec.)
Isolation capacitance
Isolation resistance
Switching frequency
Safety standards
Safety approvals
– Input variation Vin min. to Vin max.
– Load variation 10 – 100 %
– On:
– Off:
– Off idle current:
– Operating
– Case temperature
– Storage
– Input/Output
– Input/Output
– Input/Output
dual output models balanced load: 3.0 % max.
3.3 & 5 VDC models: 2000 µF
single output models: 1.0 % max.
±15 VDC models: ±220 µF
±12 VDC models: ±330 µF
±5 VDC models: ±680 µF
12 VDC models: 470 µF
15 VDC models: 330 µF
48 V models: 125 mA typ.
48 V models: 10 mA typ.
48 V models: 18 VDC / 16 VDC typ
48 V models: 100 V max.
48 V models: 5 mA typ.
24 V models: 250 mA typ.
24 V models: 20 mA typ.
24 V models: 9 VDC / 8 VDC typ.
24 V models: 50 V max.
24 V models: 10 mA typ.
1.0 A max.
EN 55022 class A, FCC part 15, level A
±2 %
1.0 % max.
10 % of rated max current (operation at lower
load condition is safe but a higher output ripple
will be experienced)
±0.02 %/°C max.
85 mVpk-pk max.
6 % max. peak variation
500 µS max. response time
200 µs typ.
>115 % of Iout max.
indefinite, automatic recovery
2.5 to 5.5 V or open circuit
–0.7 to 0.8 V or short circuit pin 3 and pin 1/2
10 mA
–40°C to +71°C
+100°C max.
–40°C to +125°C
95 % rel H max.
>1‘000‘000 h
1‘500 VDC
750 pF max.
>1‘000 Mohm
340 kHz typ. (frequency modulation PFM)
UL 60950-1, IEC/EN 60950-1
CSA File No. 226037
http://directories.csa-international.org
(entry pending)
DC/DC Converters
TES 5WI Series
Page 2 of 3
5 Watt

Related parts for TES 5-4822WI