DCA2-5CN02F1 Omron, DCA2-5CN02F1 Datasheet

no-image

DCA2-5CN02F1

Manufacturer Part Number
DCA2-5CN02F1
Description
2M THICK DNET CABLE 1F CONN.
Manufacturer
Omron
Datasheet

Specifications of DCA2-5CN02F1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
DCA25CN02F1
Environment-resistive (IP67) I/O
Terminals with Troubleshooting
Functions such as Sensor Power
Supply Short-circuit Detection
Smart Slave Functions
Ordering Information
General Specifications
52
No need to wire input device power supply (input only)
• Equipped with the standard Smart Slave functions that provide powerful
• High degree of environmental resistance with dust-proof and drip-proof
• Power supply wiring is not required for input devices.
• Connect heavy-load devices (up to 1.5 A).
• Power supply wiring is not required for input devices such as sensors. (Power supply wiring is required for output devices.)
• Detects ground faults or disconnects and notifies the Master.
Item
Communications power supply voltage
I/O power supply voltage
Noise immunity
Communications power supply current
consumption
Vibration resistance
Shock resistance
Dielectric strength
Insulation resistance
Ambient operating temperature
Ambient operating humidity
Ambient operating atmosphere
Ambient storage temperature
Degree of protection
Mounting method
Mounting strength
Connector strength
Screw tightening torque
Weight
I/O power supply connector
Communications connector
Disconnected sensor detection (input only)
Environment-resistive Terminals with Transistors (High-function Type)
DRT2-@D08C(-1)/@D16C(-1)
preventative maintenance and troubleshooting capabilities.
construction.
Connected device comments
Output
Contact operation counter
Input
Input
Input filter (input only)
Environment-resistive Terminals with Transistors (High-function Type)
NPN (+ common)
PNP (+ common)
NPN (+ common)
PNP (- common)
NPN (- common)
PNP (- common)
Specifications
Model
Network power supply voltage monitor
External load short-circuit detection (output only)
11 to 25 VDC (Supplied from the communications connector)
20.4 to 26.4 VDC (24 VDC -15%/+10%)
Conforms to IEC 61000-4-4 2 kV (power line)
115 mA max.
10 to 60 Hz, 0.7-mm double amplitude, 60 to 150 Hz, 50 m/s
Y, and Z directions
150 m/s
500 VAC between isolated circuits
20 MΩ min. (between isolated circuits)
-10°C to 55°C
25% to 85% (with no condensation)
No corrosive gases
-20°C to 65°C
IP67
M5 screw mounting (front and back)
100 N
30 N
Round connectors (communications, supply voltage, and I/O): 0.39 to 0.49 N
M5 (Unit mounting from front): 1.47 to 1.96 N
340 g max.
M12
Unit conduction time monitor
16 points
8 points
Last maintenance date
DRT2-ID08C(-1)
2
, 6 directions, 3 times each
Power-ON inrush current protection (input only)
I/O connections
Sensor I/O
connector
--
190 mA max.
DRT2-HD16C(-1)
Rated internal circuit power
communications connector
Supplied from the
I/O power supply monitor function (output only)
supply voltage
Communications speed auto-detection
·
m
Total ON time monitor
60 mA max.
390 g max.
7/8-16UN
2
for 80 min each in the X,
DRT2-OD08C(-1)
Rated I/O power supply voltage
DRT2-@D08C(-1)/@D16C(-1)
communications connector
communications connector
Supplied from the
Supplied from the
·
m
24 VDC
Communications error log function (output only)
Sensor power supply short-circuit detection (input only)
No need to wire Unit power supply
Unit comments
DRT2-ID08C
DRT2-ID08C-1
DRT2-OD08C
DRT2-OD08C-1
DRT2-HD16C
DRT2-HD16C-1
Model

DCA2-5CN02F1 Summary of contents

Page 1

Environment-resistive Terminals with Transistors (High-function Type) DRT2-@D08C(-1)/@D16C(-1) Environment-resistive (IP67) I/O Terminals with Troubleshooting Functions such as Sensor Power Supply Short-circuit Detection • Equipped with the standard Smart Slave functions that provide powerful preventative maintenance and troubleshooting capabilities. • High degree ...

Page 2

Input Specifications ● 8-point Inputs Terminals with Transistors Item Model DRT2-ID08C Internal I/O common NPN I/O points 8 inputs 9 VDC min. (between ON voltage input and V terminal) 5 VDC max. (between OFF voltage input and V terminal) OFF ...

Page 3

Wiring Diagrams DRT2-ID08C (NPN) CAN L CAN Input Input DRAIN ...

Page 4

Environment-resistive Terminals with Transistors (Standard Type) DRT2-@D04CL(-1)/@D08CL(-1)/@D16CL(-1) Remote I/O Terminals with High Degree of Environmental Resistance (IP67) in Product Lineup Including Economical Input, Output, and Mixed I/O Models • Common Smart Slave functionality provides strong support for equipment operation status ...

Page 5

General Specifications Item Model DRT2-ID04CL(-1) DRT2-OD04CL(-1) DRT2-ID08CL(-1) DRT2-OD08CL(-1) DRT2-HD16CL(-1) DRT2-WD16CL(-1) DRT2-MD16CL(-1) Communications power VDC (Supplied from the communications connector) supply voltage I/O power supply voltage 20.4 to 26.4 VDC (24 VDC -15%/+10%) Noise immunity Conforms to IEC ...

Page 6

Output Specifications ● 4-output Models Item Model DRT2-OD04CL Internal I/O common NPN I/O points 4 outputs Rated output current 0.5 A per point, 2.0 A per common 1.2 V max. (0 Residual voltage between each output terminal and ...

Page 7

Wiring Diagrams DRT2-ID04CL (NPN) CAN CAN DRAIN 24V I/O power supply 24 VDC Two-wire sensor (Limit ...

Page 8

DRT2-OD08CL (NPN) CAN CAN 24V DRAIN ? I/O power supply DRT2-OD08CL-1 (PNP) CAN CAN H ...

Page 9

DRT2-WD16CL (NPN) CAN CAN 24V DRAIN 4 Output 1 NC Output I/O power supply DRT2-WD16CL-1 (PNP) CAN CAN ...

Page 10

Peripheral Devices for Environment-resistive Slaves Peripheral Devices for DeviceNet Communications Ordering Information ● Environment-resistive Connection Products (for Thin Cable, M12 Micro Connectors) Product Appearance Sealed Assembling-type Connector (male) Sealed Assembling-type Connector (female) Sealed T-branch Connector Sealed Connector with Terminating Resistor ...

Page 11

Environment-resistive Models (for Thin Wires and M12 Micro Connectors) Product Appearance Sealed T-branch Connector Sealed Assembling type Connector (female) Connectors with Shielded Cables Shielded Branch Relay Box Model DCN2-1S For 1 branch line DRS2-1S Plug DRS2-2S Socket DCA1-5CSC5W1 Length ...

Page 12

... Socket) Peripheral Devices 166 Model DCN3-11 T-branch Connector DCN3-12 T-branch Connector (Branch connector is M12.) DRS3-1 Plug DCA2-5CN01W1 Length (L DCA2-5CN02W1 Length (L DCA2-5CN05W1 L Length (L DCA2-5CN10W1 Length (L DCA2-5CN01F1 Length (L DCA2-5CN02F1 Length (L DCA2-5CN05F1 Length (L DCA2-5CN10F1 Length (L DCA2-5CN01H1 Length (L DCA2-5CN02H1 Length (L DCA2-5CN05H1 L Length (L DCA2-5CN10H1 Length (L DCA1-5CN01W5 ...

Page 13

... DCN3- Connectors with Terminating Assembling-type Connector Resistor XS2@-D5S7 DRS2-@ -- Connectors with Terminating Branch Relay Box Resistor DCN2-S@C5H DRS2-@S 1,000 VAC for 60 seconds -- Connectors with Panel Mounting Terminating Resistor Connector DRS3-1 DCA2-5CNC5P1 for 15 s Peripheral Devices Panel Mounting Connector XS4M-D521-1 -- 167 ...

Page 14

Dimensions ● Environment-resistive Connection Products (for Thin Cable, M12 Micro Connectors) Cables with Connectors on Both Ends DCA1-5CN@@ M12 Cables with Connector on Single End (Socket) DCA1-5CN@@ M12 Cables with ...

Page 15

Panel-mounting Connector (Socket) with 0.5 m Cable DCA1-5CNC5P1 M16 nut XS2P-D522-2 Panel-mounting Connector (Socket), Solder-cup Terminals XS2P-D522 Panel-mounting Connector (Plug) with 0.5 m Cable DCA1-5CNC5M1 M16 nut ...

Page 16

Environment-resistive Models (for Thin Wires and M12 Micro Connectors) Cables with Connectors on Both Ends DCA1-5CS@@ M12 Cables with Connector on Single End (Socket) DCA1-5CS@@ M12 Cables with Connector ...

Page 17

Shielded Branch Relay Box with Four Ports DCN2-S4C5H1 54 27 4.5 dia 13.5 Shielded Branch Relay Box with Eight Ports DCN2-S8C5H1 13.5 Connections Diagram 4.5 ...

Page 18

... Thin Cable with Connectors on Both Ends (5 Conductors for Communications) DCA1-5CN@@ Thin Cable with Panel-mounting Connector Socket on One End (5 Conductors for Communications) DCA2-5CNC5P1 Note: A rubber seal and nut for panel mounting are included. Peripheral Devices 172 L 61.2 62.5 12 dia. 26 dia. ...

Page 19

... Panel-mounting Connector (Plug) with 0.5 m Cable DCA2-5CNC5M1 1 2 T-branch Connector (5 Conductors for Communications, Thick Wire Branch Line) DCN3-11 Connections Diagram Wiring Terminal No. Plug CN0 (IN) Socket CN2 (OUT Socket CN1 (OUT) T-branch Connector (5 Conductors for Communications, Thin Wire Branch Line) DCN3-12 Connections Diagram Wiring Terminal No ...

Page 20

Connector (Plug) with Terminating Resistance DRS3-1 Wiring Terminal No. Note: Terminating resistance (121 Ω dia Peripheral Devices 174 Panel-mounting Connector (5 Pins for Communications) XS4M-D521-1 Name DRAIN : ...

Page 21

... Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority ...

Page 22

... São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br OMRON ELECTRONICS MEXICO • HEAD OFFICE Apodaca, N.L. • 52.811.156.99.10 • 001.800.556.6766 • mela@omron.com OMRON EUROpE B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) 23 568 13 00 Fax: +31 (0) 23 568 13 88 www.industrial.omron.eu Q102-E1-11_DRT2_IP67 08/10 OMRON ARGENTINA • ...