Specifications of G79-A500C

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G79A500C
Ordering Information
Reduces Wiring while Providing I/O
Flexibility
1
1
1
1
1
1
3 RELAY TERMINAL BLOCK BASE
Relays not included. Order below.
Note: Each relay to be mounted must incorporate a coil that has proper specifications within the maximum rated voltage range.
3 PCB/SSR RELAYS FOR USE WITH G70A
Note: G2R-13-SN has twin cross-bar contacts.
3 CONNECTING SOCKETS FOR SINGLE POINT RELAY CONNECTION
Output
Input
Output
Input
1 pole (G2R input relays are SPST-NO)
2 poles (G2R output relays are SPDT)
Relay I/O Block Base
Standard Relays and SSRs can be
mounted together in the same base
Terminal block incorporates finger-touch
protection from electric shock,
conforming to VDE 0106
Connects to PLCs and SBCs easily with
a connector
Mounts on DIN rail track
SPDT (Form C) switching provided
when G2R output relays are installed
G70A I/O Blocks are UL, CSA, IEC,
VDE, SEV, SEMKO, DEMKO, and SET1
approved when filled with G2R relays
and G3R SSRs
Classification
Classification
NPN (+ common)
PNP (-- common)
NPN/PNP (to the relay)
NPN: G70A-ZOC16-3 DC24V
PNP: G70A-ZOC16-4 DC24V
G70A-ZIM16-5 DC24V
Number of poles
Internal I/O circuit common
9
I/O Block Base
G2R-1-SND DC24
G2R-1-SND DC12
G2R-1A3-SND DC24V
G2R-13-SND DC24V
24 VDC
24 VDC
110 VDC max., 240 VAC max.
(See Note)
PCB Relay
P2RF-05-E
P2RF-08-E
Rated voltage
Part number
G3R-OA202SZN DC5-24
G3R-ODX02SN DC5-24
G3R-OD201SN DC5-24
G3R-IAZR1SN AC100-240
G3R-IDZR1SN DC12-24
G3R-IDZR1SN DC5
G70A-ZOC16-3 DC24V
G70A-ZOC16-4 DC24V
G70A-ZIM16-5 DC24V
Solid State Relay
G70A
Part number
èò

G79-A500C Summary of contents

Page 1

Relay I/O Block Base Reduces Wiring while Providing I/O Flexibility 1 Standard Relays and SSRs can be mounted together in the same base 1 Terminal block incorporates finger-touch protection from electric shock, conforming to VDE 0106 1 Connects to ...

Page 2

... G70A Part number G79-Y100C G79-Y150C G79-Y200C G79-Y300C G79-Y500C G79-A200C G79-A500C Part number G79-100C G79-150C G79-200C G79-300C G79-500C G79-I100C-75 G79-I150C-125 G79-I200C-175 G79-I300C-275 G79-I500C-475 ...

Page 3

G70A Specifications 3 RELAY BLOCK BASE Item G70A-ZOC16-3 Contact resistance 10 mˆ (excluding the resistance of the relay to be used) Permissible current 10 A Max. operating voltage 380 VAC, 125 VDC Dielectric strength 4,000 VAC, 50/60 Hz for 1 ...

Page 4

G70A 3 PCB RELAYS G2R-1A3-SND AND G2R-13-SN (SND) Coil Ratings Rated voltage 230 VAC Rated current 3.1 mA 30,000 ˆ Coil resistance Must operate voltage 80% max. of rated voltage Must release voltage 30% ...

Page 5

G70A Characteristics for G3R I/O Relay Input Relay Item Operate time 20 ms max. Release time Response frequency 10 Hz Output ON voltage drop 1.6 V max. Leakage current 5 A max. Insulation resistance 100 Mˆ min. at 500 VDC ...

Page 6

G70A Unit: mm (inch) G70A-ZIM16 (Input) 3 P2RF P2RF-05-E M3.5 screw 85.5 max. (3.37) 16.0 max. (0.63) P2RF-08-E 1.5 M3 screw 2 85.5 max. 3.5 dia. hole 5 16.0 max. (0.63) 6 234 (9.21) M3.5 Terminal Arrangement 59 max. (Top ...

Page 7

... G79-OPC-P --- G79-YPC/G79-APC --- G70A-ZIM16-5 G70A-ZOC16-3 --- G79-PC G79-PC --- --- G79-OPC-P G79-OPC-P --- G79-YPC/G79-APC --- --- --- G79-PC-P-P G79-PC-P-P --- --- G70A-ZIM16-5 G70A-ZOC16-3 --- G79-PC G79-YPC/G79-APC --- G79-YPC/G79-APC --- --- --- G79-OPC-P With loose wires Length (O) Model 2 m G79-A200C 5 m G79-A500C G70A G70A-ZOC16-4 --- --- --- --- G79-YPC/G79-APC G70A-ZOC16-4 --- --- --- --- --- --- --- --- --- G79-YPC/G79-APC G79-YPC/G79-APC --- --- --- G79-PC-P-P G79-PC-P-P G70A-ZOC16-4 --- --- --- --- --- --- G79-YPC/G79-APC --- --- With connector Length (O) Model 1 m G79-100C 1 ...

Page 8

... G70A G79-YPC Cable with Loose Wires and Crimp Terminals Convenient for connecting screw terminals to I/O Terminal Blocks Connections Tube no. Wire no. Side G79-APC Cable with Loose Wires Device connection end provides loose wires. 8 Side A Connecting to devices Note: 1. Keep the line capacity per I/O or less. Also, check the capacity of the relay drive element against the power consumption of the I/O relay before output applications ...

Page 9

... G70A Connections Tube no. Wire no. Side A Light brown 1 Yellow 2 3 Light green 4 Gray 5 White 6 Light brown 7 Yellow 8 Light green 9 Gray 10 White G79-PC Cable with Connector (1:1) Convenient for 1:1 connection of PLC I/O modules to I/O Relay Blocks. Side A Color of insulator Dot mark Connections PLC connector pin no ...

Page 10

... No. of output points CS1W-ID291 96 inputs CS1W OD29 CS1W-OD29P 96 96 outputs t t CS1W-MD29P CS1W-MD29 48 inputs/48 outputs 48 inputs/48 outputs Note: For cable pin-outs, refer to the G79 Data Sheet in the Cables section of this catalog. 10 Side A Straight-line distance (no curves) For input B Model G79-I100C-75 G79-I150C-125 G79-I200C-175 G79-I300C-275 G79-I500C-475 ...

Page 11

G70A Installation 3 TERMINAL ARRANGEMENT/INTERNAL CONNECTION G70A-ZOC16-3 (NPN) Connector Terminal Arrangement (Top View) G70A-ZOC16-4 (PNP) Connector Terminal Arrangement (Top View) G70A 11 ...

Page 12

... Note: 1. When G70A-ZIM16-5 is used with C200H-ID216 Input Module and a G79-IPPC cable, the G70A common terminal must be connected to +24 VDC. The C200H-ID216 common pins (A9, B9, A18, B18) are connected When G70A-ZIM16-5 is used with C200H-ID215 Input Module and a G79-CP cable, the G70A common terminal must be con- nected to +24 VDC. The C200H-ID215 common pins (A9, B9, A18, B18) are connected ...

Page 13

... G70A NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4. 9 OMRON ELECTRONICS, INC. One East Commerce Drive Schaumburg, IL 60173 1-800-55-OMRON Cat. No. GC RIO-1 04/00 Specifications subject to change without notice. G70A OMRON CANADA, INC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 416-286-6465 Printed in U ...