B7A-R6F31 Omron, B7A-R6F31 Datasheet
![no-image](/images/manufacturer_photos/0/4/494/omron_sml.jpg)
B7A-R6F31
Specifications of B7A-R6F31
B7A-R6F31 Summary of contents
Page 1
... B7A Link Remote I/O Components Overview Parts Summary and Configuration Guide to Build a Wire-Saving B7A Link Remote I/O System 1 Just two wires transmit data, simplifies installation and troubleshooting 1 High-speed (100 m max ms) and long distance (500 m max. at 19.2 ms) configurations available 1 Wide range of transistor and relay ...
Page 2
... B7A-R6B11 UL CSA CSA LOAD OFF B7A-R6B31 CE (See (S HOLD B7A-R6C11 Note 5) Note 5) LOAD OFF B7A-R6C31 HOLD B7A-R6F11 LOAD OFF B7A-R6F31 HOLD B7A-R6G11 LOAD OFF B7A-R6G31 HOLD B7A-R6B16 LOAD OFF B7A-R6B36 HOLD B7A-R6C16 LOAD OFF B7A-R6C36 HOLD B7A-R6F16 LOAD OFF B7A-R6F36 HOLD B7A-R6G16 ...
Page 3
... The previous output condition will be on hold when an error results. LOAD OFF: All outputs will be OFF when an error results. 2. These G70D Relay Output Link Modules cannot be connected to high-speed B7A. 3. Information on EC Directives Individual OMRON products that comply with EC Directives conform to the common emission standards of EMC Directives. ...
Page 4
... The previous output condition will be on hold when an error results. LOAD OFF: All outputs will be OFF when an error results. 2. The 10-point B7A-T10S1 and 10-point B7A-T10S3 are different from each other in terminal configuration. 3. Information on EC Directives Individual OMRON products that comply with EC Directives conform to the common emission standards of EMC Directives. ...
Page 5
... B7A Link Overview Configuration Guidelines 3 16-POINT TRANSISTOR I/O LINK MODULES Input (Transmission) Screw terminal model B7A B7AS PCB model B7A Link master adapter (16 points) B7A Link master adapter (32 points) B7A Note: The I/O delay time values of 16-point Link Terminals with Adapters are either 3 ms (typical, for high-speed models) or 19.2 ms (typical, for normal-speed models) ...
Page 6
... B7A Link Overview 3 MIXED I/O LINK MODULES 16 Inputs/16 Output or 8 Inputs/8 Outputs Screw terminal model (16 input and 16 output points) B7AM Screw terminal model (8 input and 8 output points) B7AM Note: The Mixed I/O Link Terminals are either 3 ms (typical, for high--speed models) or 19.2 ms (typical, for normal--speed models). ...
Page 7
... NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4. 9 OMRON ELECTRONICS, INC. One East Commerce Drive Schaumburg, IL 60173 1-800-55-OMRON Cat. No. GC RIO-1 04/00 Specifications subject to change without notice. B7A Link Overview OMRON CANADA, INC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 416-286-6465 Printed in U.S.A. ...