Operation
3-6-2 Setting Direct Input (When UP-01 is 13 or 14)
With direct input, the control inputs (P.IN0 to 7), position data (7 + 1/2 digits BCD), sign bit, I (incremen-
tal value) or A (absolute value) designation bit, and speed data (2 digits BCD) are taken in order.
P.OUT0 to 4 (position selection 1 to 4, speed selection ) are output as timing signals for taking the data.
Data is taken on the falling edge of the P.OUT signal. When setting data from the Programmable Con-
troller, output the data between the time that P.OUT turns ON and turns OFF. The time that P.OUT
stays ON for can be set by PP-26 (selection signal output time).
PTP Data Display Example
Parameter number (Pd01H) display
Data display (Pd01H contents)
Parameter number (Pd01L) display
Data display (Pd01L contents)
Parameter number (Pd01F) display
Data display (Pd01F contents)
Parameter number (Pd01A) display
Data display (Pd01A contents)
Parameter number (Pd01r) display
Data display (Pd01r contents)
When PP-01 (minimum setting unit)
is set to “0.0001,” zeroes following
the decimal point are not displayed.
Rightmost digit flashes.
Indicates incremental
value designation.