B7AP-M1C Omron, B7AP-M1C Datasheet
B7AP-M1C
Specifications of B7AP-M1C
B7AP-M1C Summary of contents
Page 1
... Ordering Information Classification Appearance Stationary Unit M30 Moving Unit M30 Note: The B7AP-S1 Power Coupler has a gauge that is used to adjust the transmission distance between the B7AP-S1 and B7AP-M1 Power Couplers. Transmission distance I/O delay (couplers) Typical: 19.2 ms 8±1.5 mm Max (0.32 in ± ...
Page 2
... Refer to Power Supplies in Operation Section of this data sheet. 2. The maximum I/O points are the same as the maximum input points of the B7A Input Unit connected to the B7AP-M1. 3. PLCs and three-wire sensors can be connected only if the B7A Input and Output Units are each connected with an independent power supply ...
Page 3
... N (5 kgf) (11 lbs (400 kgf S cm) (28 lbf) IEC IP67 2 m (78.7 in) Approx. 300 g (10.58 oz) Radiated Emissions: EN55022 class A Radiated Immunity: prEN50082-2 Electrostatic Discharge: prEN50082-2 Burst Transients: prEN50082-2 UL508 Conforms to EN50081-2, EN50082-2 12 VDC ±10 B7AP B7AP-M1 --- --- Approx. 230 g (8.11 oz) 3 ...
Page 4
... Unit (96 m max.) Total length: 500 m max. Note: 1. The thickness of the extension cable for the B7AP-S1 or B7AP-M1 Power Coupler must be 0.75 mm min. 2. For transmitting signals only, the brown lead wire of the B7AP-M1 Power Coupler must not be used. Insulate the brown lead wire with insulation tape so that the brown wire will not come in contact with any lead wire ...
Page 5
... Lit when power is supplied to the Power Coupler. Not lit when power is not supplied to the Power Coupler. Lit when the B7AP-M1 and B7AP-S1 Power Couplers are properly set for wireless signal or power transmission at a transmission distance of 8 ±1.5 mm. (0.32 ±0.06). Not lit when the B7AP-M1 and B7AP-S1 Power Couplers are not properly set for wireless signal or power transmission, or the B7AP-M1 Power Coupler has excessive loads ...
Page 6
... Power Couplers operate normally before they are put in actual operation. Correct Power or high-tension line Do not subject the head of the B7AP-S1 or B7AP-M1 Power Coupler to excessive shock with hard objects. Do not use the B7AP-S1 or B7AP-M1 Power Coupler outdoors unless it is properly protected. ...
Page 7
... J TRANSMISSION DISTANCE FOR STABLE SIGNAL AND POWER TRANS- MISSION The B7AP-S1 Power Coupler has a gauge that is used to adjust the transmission distance between the B7AP-S1 and B7AP-M1 Power Couplers. Use the gauge to adjust the transmission distance to 8 mm, make sure that the green operation indicator of the B7AP-M1 Power Coupler is lit, and the B7A Output Unit has no error output before operating the Power Couplers ...
Page 8
... OMRON ELECTRONICS LLC One East Commerce Drive Schaumburg, IL 60173 1-800-55-OMRON Cat. No. CEDSAX4 11/01 OMRON ON- - LINE Global - - http://www.omron.com USA - - http://www.omron.com/oei Canada - - http://www.omron.com/oci Specifications subject to change without notice. B7AP OMRON CANADA, INC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 416-286-6465 Printed in U.S.A . ...