Page 1
Projects a proximity field through air ! ! ! ! Less expensive than many mechanical switches ! ! ! ! Sensitivity easily adjusted via capacitor value ! ! ! ! Turns small objects into intrinsic touch ...
Page 2
OVERVIEW The QT113 is a digital burst mode charge-transfer (QT) sensor designed specifically for touch controls; it includes all hardware and signal processing functions necessary to provide stable sensing under a wide variety of changing conditions. Only a ...
Page 3
Cx than a solid plane. Sensitivity may even remain the same, as the sensor will be operating in a lower region of the gain curves. 1.3.2 K ’ C ...
Page 4
Shielding Against Fringe Fields Figure 1-5 Sen se Sense wire U nshielded Electrode 4-1 to 4-3). The value of Cs also has a dramatic effect on sensitivity, and this can be increased in value ( limit). Also, increasing ...
Page 5
To prevent this, the sensor includes a timer which monitors detections detection exceeds the timer setting, the timer causes the sensor to perform a full recalibration (when not set to infinite). This is known as the Max ...
Page 6
Figure 2-3 Getting HearBeat pulses with a pull-down resistor + eartBeat™ P ulses GAIN ...
Page 7
Figure 3-1 ESD Suppression Circuit + OUT PT1 G AIN PT2 digital spikes, sags, ...
Page 8
ABSOLUTE MAXIMUM SPECIFICATIONS Operating temp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 9
DC SPECIFICATIONS Vdd = 3.0V 10nF 5pF, T Parameter Description V Supply voltage DD I Supply current DD V Supply turn-on slope DDS V Low input logic level IL V High input logic level HL ...
Page 10
ORDERING INFORMATION PART QT113-D QT113-S QT113-IS QT113H-D QT113H-S QT113H-IS Chart 4-3 - Typical Response Time vs. Cx; Vdd = 3.0 100.00 10.00 1. Load TEMP RANGE PACKAGE 0 - 70C 0 - 70C -40 ...
Page 11
Package type: 8-pin Dual-In-Line Millimeters SYMBOL Min a 6.096 A 7.62 M 9.017 m 7.62 Q 0.889 P 0.254 L 0.355 L1 1.397 F 2.489 R 3.048 r 0.381 S 3.048 7.62 x 8.128 Y 0.203 Millimeters ...
Page 12
Quantum Research Group Ltd Enterprise House, Southampton, Hants SO14 3XB Tel: +44 (0)23 8045 3934 Fax: +44 (0)23 8045 3939 This device expressly not for use in any medical or human safety related application without the express written consent of ...