A16-30-10-110V-50HZ ABB, A16-30-10-110V-50HZ Datasheet - Page 4

no-image

A16-30-10-110V-50HZ

Manufacturer Part Number
A16-30-10-110V-50HZ
Description
POWER RELAY, 110VAC, 17A, 3PST, PANEL
Manufacturer
ABB
Datasheet

Specifications of A16-30-10-110V-50HZ

Operating Voltage
690VAC
Switching Power Ac1
7.5kW
Switching Power Ac3
7.5kW
Switching Current Ac1
30A
Switching Current Ac3
17A
Load Current Inductive
17A
Load Current Resistive
30A
1
1
1.4
1SXU 000 023 C0201
Application
A-Line contactors are mainly used for controlling 3-phase motors and for
controlling power circuits corresponding to their operating characteristics up to
690 and even 1000 VAC. and 440 VDC.
Control circuit types
AE types: with laminated magnetic circuit and double-winding coil fed from DC
supply via a CDL5 insertion contact mounted on the device. The CDL5 has an NC
lagging contact for insertion of the second winding. (See schematic.)
Quick mounting on DIN rail: EN 50022 and
EN 50023 standards:
35 x 7.5
35 x 15
75
Location of side mounted accessories: on right
or left hand side. Factory mounted on left hand
side for CAL5 on A50 - A300
• right hand side for CDL5/CCL5 on
Holes for screw mounting (screws not supplied).
Distance between holes according to EN 50003.
Terminals delivered in open position with captive
screws (unused terminal screws must be
tightened).
Screwdriver guidance for all terminals makes it
possible to use motorized screwdrivers.
All terminals provide protection against accidental
direct contact with live parts according to
VDE0106 - Part. 100.
All AE9 - AE40 contactor terminals as well as
AE45 - AE110 contactor auxiliary contact and
coil terminals ensure IP20 degree of protection
according to IEC 947-1.
mm
AE45 - AE110
for AE45 - AE110
mm
mm
for AE9 - AE75
for AE9 - AE40
Frame size
Power pole
30 = 3 NO
40 = 4 NO
22 = 2 NO & 2 NC
General information
AE9 - AE110, DC operated
UL rated, 3 phase
Catalog number explanation
AE9-30-00-81
AE9 - AE110
Coil voltage selection chart
Uc (DC)
For other voltages, see page 1.26.
A1
DC
Hz
A2
B2 - Holding
B1 - Pull-in
AE9 to AE40
Contr.
type
AE
A3
12
80
NC contact in
4th contactor
pole
24
81
Terminal screws:
• Posidrive (+,-) No° 2 for all AE9 - AE75
• M8 hex threaded socket screw for AE95 & AE110
Location of surge suppressors.
Clear marking of coil voltages and frequencies.
Connecting point for control leads in top part of
main terminals of AE50 - AE75 contactors. For
AE95 & AE110 contactors these are additional
power connections.
Terminal marking according to IEC 947-4-1,
EN 50005, EN 50012 and NEMA standards.
Location of function marker.
Stops for attaching front mounted accessories.
Coil voltage
(see coil voltage selection chart)
Auxiliary contacts
00 = No auxiliary provided
11 = 1 NO & 1 NC
48
83
Volts
Uc (DC)
A1
ABB Inc. • 888-385-1221 • www.abb-control.com
A2
Low Voltage Products & Systems
110
86
B2 - Holding
B1 - Pull-in
AE45 to AE110
125
87
A3
CDL5 (AE45 to AE75)
CCL5 (AE95 to AE110)
220
88
240
89