BMA250 SHUTL Bosch Sensortec, BMA250 SHUTL Datasheet - Page 46

BMA250 DAUGHTERCARD FOR DEV KIT

BMA250 SHUTL

Manufacturer Part Number
BMA250 SHUTL
Description
BMA250 DAUGHTERCARD FOR DEV KIT
Manufacturer
Bosch Sensortec
Series
-r
Datasheets

Specifications of BMA250 SHUTL

Featured Product
BMA250 - Digital, Triaxial Acceleration Sensor
Sensor Type
Accelerometer, 3 Axis
Sensing Range
±2g, 4g, 8g, 16g
Interface
-
Sensitivity
256LSB/g, 128LSB/g, 64LSB/g, 16LSB/g
Voltage - Supply
-
Embedded
No
Utilized Ic / Part
BMA250
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
828-1024
(0x24) low_hy sets the hysteresis of the low-g interrupt. An LSB of (0x24) low_hy corresponds
to an acceleration difference of 125 mg. Default value of (0x24) low_hy is ´01b´.
(0x24) high_hy sets the hysteresis of the high-g interrupt. The meaning of an LSB of (0x24)
high_hy depends on the selected g-range. It corresponds to an acceleration difference of 125
mg in 2g-range, 250 mg in 4g-range, 500 mg in 8g-range, and 1000mg in 16g-range.
Default value of (0x24) high_hy is ´10b´.
Register (0x25) contains the delay time definition for the high-g interrupt. The physical delay
time can be computed from the content of (0x25) high_dur according to
delay [ms] = [(0x22) high_dur + 1] • 2 ms. Possible delay times range from 2 ms to 512 ms.
Default value of (0x25) high_dur is 0x0F, corresponding to a delay of 32 ms.
Register (0x26) contains the threshold definition for the high-g interrupt. The meaning of an
LSB of (0x26) high_th depends on the selected g-range. It corresponds to 7.81 mg in 2g-range,
15.63 mg in 4g-range, 31.25 mg in 8g-range, and 62.5 mg in 16g-range.
Default value of (0x26) high_th is 0xC0.
Register (0x27) contains the definition of the number of samples to be evaluated for the slope
interrupt (any-motion detection). The number of samples is N = (0x27) slope_dur + 1.
Default value of (0x27) slope_dur is ´00b´.
Rev. 1.0
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such
as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
Table 49: Threshold definition for the low-g interrupt, register (0x24)
Table 50: Delay time definition for the high-g interrupt, register (0x25)
Table 51: Threshold definition for the high-g interrupt, register (0x26)
Table 52: Samples number definition for the slope interrupt, register (0x27)
reserved
dur<7>
hy<1>
th<7>
high_
high_
high_
Bit 7
Bit 7
Bit 7
Bit 7
reserved
dur<6>
hy<0>
th<6>
high_
high_
high_
Bit 6
Bit 6
Bit 6
Bit 6
reserved
reserved
dur<5>
th<5>
high_
high_
Bit 5
Bit 5
Bit 5
Bit 5
Page 46 / not for publishing
reserved
reserved
dur<4>
th<4>
high_
high_
Bit 4
Bit 4
Bit 4
Bit 4
Data sheet
BMA250
reserved
reserved
dur<3>
th<3>
high_
high_
Bit 3
Bit 3
Bit 3
Bit 3
reserved
dur<2>
th<2>
mode
high_
high_
Bit 2
Bit 2
Bit 2
Bit 2
low_
dur<1>
dur<1>
slope_
hy<1>
th<1>
high_
high_
Bit 1
Bit 1
Bit 1
Bit 1
low_
Bosch Sensortec
03 March 2011
dur<0>
dur<0>
slope_
hy<0>
high_
high_
th<0>
Bit 0
Bit 0
Bit 0
Bit 0
low_