Current Transducer LTSR 25-NP
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
I
I
V
V
N
R
C
R
TCR
V
I
X
TCV
TC
V
TCV
t
t
di/dt
f
T
T
m
Notes : see overleaf.
LEM
PN
P
C
ra
r
REF
C
OM
A
S
OUT
IM
L
L
L
S
Electrical data
Accuracy - Dynamic performance data
General data
REF
OUT
G
IM
Primary nominal r.m.s. current
Primary current, measuring range
Analog output voltage @ I
Voltage reference (internal reference), refout mode
Voltage reference (external reference), refin mode
Number of secondary turns (± 0.1 %)
Load resistance
Max. capacitive loading
Internal measuring resistance (± 0.5 %)
Thermal drift of R
Supply voltage (± 5 %)
Current consumption @ V
Accuracy @ I
Accuracy with R
Linearity error
Thermal drift of V
Thermal drift of the gain
Residual voltage @ I
Thermal drift of internal V
Reaction time @ 10 % of I
Response time @ 90 % of I
di/dt accurately followed
Frequency bandwidth (0 .. - 0.5 dB)
Ambient operating temperature
Ambient storage temperature
Mass
Standards
PN
, T
IM
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
OUT
IM
A
@ I
= 25°C
/ V
P
PN
= 0, after an overload of 3 x I
(- 0.5 .. 1 dB)
REF
, T
I
REF
P
P
C
@ I
PN
A
= 0
= 5 V
PN
= 25°C
@ I
P
= 0
P
= 0 - 10°C .. + 85°C
- 40°C .. + 85°C
- 40°C .. + 85°C
- 40°C .. - 10°C
10 x I
5 x I
Typ
PN
PN
PN
± 2.0
± 2.0
100
25
0 .. ± 80
2.5
2.5
2.5
1.9 .. 2.7
2000
500
50
< 50
5
28 + I
± 0.2
± 0.7
< 0.1
± 0.5
50
< 100
< 400
> 60
DC .. 100
DC .. 200
- 40 .. + 85
- 40 .. + 100
10
EN 50178 : 1997
I EC 60950-1 : 2001
2
±
2)
3)
S
(0.625
5)
37.5
Max
50
+ (V
1)
6)
4)
OUT
·
/R
I
ppm/K
ppm/K
ppm/K
ppm/K
ppm/K
P
L
/I
) mA
A/µs
PN
kHz
kHz
mV
mV
mV
k
pF
n s
n s
°C
°C
) V
At
At
%
%
%
g
V
V
V
V
I
Features
Advantages
Applications
Application Domain
PN
Closed loop (compensated) multi-
range current transducer using the
Hall effect
Unipolar voltage supply
Insulated plastic case recognized
according to UL 94-V0
Compact design for PCB mounting
Incorporated measuring resistance
Extended measuring range
Access to the internal voltage
reference
Possibility to feed the transducer
reference from external supply.
Excellent accuracy
Very good linearity
Very low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding
applications.
Industrial.
Copyright protected.
= 25 At
w w w .lem.com
051123/6
Page 1/3