HC2F100-SN LEM USA Inc, HC2F100-SN Datasheet - Page 4

no-image

HC2F100-SN

Manufacturer Part Number
HC2F100-SN
Description
CURRENT SENSOR 100APOLAR
Manufacturer
LEM USA Inc
Series
HC2Fr
Datasheet

Specifications of HC2F100-SN

Current - Sensing
±100A
Accuracy
-
Sensitivity
20mV/A
Current - Supply
15mA ~ 20mA
Sensor Type
Open Loop Hall Effect
Voltage - Supply
4.75 V ~ 5.25 V
Output
Analog, Ratiometric
Frequency
20kHz
Response Time
15µs
Polarization
Bidirectional
Operating Temperature
-40°C ~ 125°C
Package / Case
Module
Other names
Q3206052
071113/1
Absolute maximum ratings (not operating)
Operating characteristics
Maximun peak primary current (not operating)
Primary nom inal DC or rms current
Maximun supply voltage (not operating)
Secondary maximum admissible power
Ambient operating temperature
Ambient storage temperature
Electrostatic discharge voltage
Maximum admissible vibration
Rms voltage for AC isolation test
Primary current, measuring range
Supply voltage
Analog output voltage (1)
Sensitivity (1)
Offset voltage (1)
Current consumption
Load resistance
Output internal resistance
Sensitivity error
Electrical offset current
Magnetic offset current
Temperature coefficient of
Temperature coefficient of G
Linearity error
Response time
Frequency bandwidth (2)
Output voltage noise peak-peak
Output voltage noise rms
-100
-80
-60
Parameter
-40
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
-20
Prim ary current Ip (A)
V
3.5
2.5
1.5
0.5
I
3
2
1
0
OE
OE
0
Symbol
TCV
V
TCI
V
R
TCG
20
V
V
V
BW
no rms
I
I
I
V
V
no p-p
R
G
I
OUT
OE
OM
PM
t
OM
out
OE
C
r
C
O
L
G
L
OE
OE
40
HC2F100-SN CLIPS
mA/°C
mV/°C
60
%/°C
% I
Unit
V/A
kHz
mA
mV
mV
mV
mV
@25
-20°C < T° < 85°C
- 40°C < T° < 125°C
µs
%
A
V
V
V
A
A
P
80
Symbol
V
P
I
V
P maxi
C maxi
S maxi
I
T
T
V
PN
ESD
100
A
S
d
V
0.0196
2.481
Performance Data
-0.25
-0.14
-0.04
Mini
-100
4.75
OUT
-2.0
-0.7
-1.0
-14
20
-5
-7
2
Electrical Data
-
-
-
-
-
= V
Notes:
Specification
C
/5 x (2.5 +0.020 x I )
Typical
± 0.15
± 0.08
± 0.02
0.020
m.s
± 0.7
± 0.2
5.00
0.25
Unit
m W
± 5
2.5
± 3
± 4
15
15
35
°C
°C
3
A
A
V
V
V
-
-
-
-
1)
2)
-2
The output voltage V
on the supply voltage V
The V
following formula:
Small signal only to avoid excessives heatings of the
magnetic core
Ip
0.0204
Defined by busbar to have T°
Defined by busbar to have T°
2.519
Maxi
5.25
0.25
0.14
0.04
100
2.0
0.7
1.0
C
14
20
10
20
43
5
7
4
-
-
value must be measured and used with the
Vout
@ - 40°C < T° < 125°C
@ - 40°C < T° < 125°C
@ - 40°C < T° < 125°C
@ T
@ V
@ - 40°C < T° < 125°C; 4.75 V < V
@ T
@ V
@ After excursion to ± I
@ - 40°C < T° < 125°C; V
@ - 40°C < T° < 125°C; V
@ I
@ di/dt = 50 A/µs; I
@ -3 dB; I
@ T
@ T
- 40 < T
- 40 < T
P
Specification
A
A
A
A
C
C
; V
Vc
2
= 25°C; V
= 25°C, V
= 25°C; 0 Hz < f < 1 MHz
= 25°C; 0 Hz < f < 1 MHz
= 5.00 V; T
= 5.00 V; T
C
2000
2000
OUT
= 5.00 V, T
150
100
T
*
A
S
7
X
= 20 A rms
C
< 125°C
< 125°C
is fully ratio-metric and depends
G
1
C
C
*
X
= 5 V
A
= 5.00 V; Gth = 0.020
A
= 25°C; I
Vc
Conditions
T
= 25°C
5
A
= 100 A
= 25°C
P
; T
150°C
150°C
C
C
A
With G in (V/A)
= 5.00 V
= 5.00 V
P
= 25°C
= 0 A
www.lem.com
see page 6/6
see page 6/6
C
Conditions
< 5.25 V
Page 4/ 6

Related parts for HC2F100-SN