MAX4899EETE+ Maxim Integrated Products, MAX4899EETE+ Datasheet - Page 5

IC MULTIPLEXER DUAL 3X1 16TQFN

MAX4899EETE+

Manufacturer Part Number
MAX4899EETE+
Description
IC MULTIPLEXER DUAL 3X1 16TQFN
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX4899EETE+

Function
Multiplexer
Circuit
2 x 3:1
On-state Resistance
7 Ohm
Voltage Supply Source
Single Supply
Voltage - Supply, Single/dual (±)
2.7 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
16-TQFN Exposed Pad
Product
Multiplexer
Number Of Lines (input / Output)
3.0 / 1.0
Supply Voltage (max)
3.6 V
Supply Voltage (min)
2.7 V
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Number Of Input Lines
3.0
Number Of Output Lines
1.0
Power Dissipation
1667 mW
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
MAX4899E
7, 8
10
11
12
13
14
15
16
1
2
3
4
5
6
9
USB 2.0 High-Speed, Fault-Tolerant 3:1, 4:1
PIN
MAX4899AE
_______________________________________________________________________________________
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
9
COM
COM
USB3+
USB2+
USB1+
USB0+
NAME
USB3-
USB2-
USB1-
USB0-
GND
N.C.
EN
QP
V+
C
C
EP
1
0
A
A
+
-
Ground
Analog Switch Common D+ Terminal
Analog Switch Common D- Terminal
Positive Supply-Voltage Input. Connect V+ to a 2.7V to 3.6V supply voltage. Bypass V+
to GND with a 0.1µF capacitor placed as close as possible to the device.
Digital Control Input 1. C
Functional Diagrams section.
Digital Control Input 0. C
Functional Diagrams section.
No Connection. Not internally connected.
Analog Switch 3 D- Terminal
Analog Switch 3 D+ Terminal
Analog Switch 2 D- Terminal
Analog Switch 2 D+ Terminal
Analog Switch 1 D+ Terminal
Analog Switch 1 D- Terminal
Analog Switch 0 D+ Terminal
Analog Switch 0 D- Terminal
Active-Low Enable Input. For normal operation, drive EN low. Drive EN high to place all
channels in a high-impedance state. The internal charge pump is turned off when EN is
a logic-high.
Active-Low Charge-Pump Enable Input. Drive QP low for normal operation. Drive QP
high to disable the charge pump with the switches still active at a reduced analog signal
range and higher R
Exposed Paddle. Connect EP to GND.
ON
.
1
1
and C
and C
0
0
control the analog signal path as shown in the
control the analog signal path as shown in the
FUNCTION
Multiplexers
Pin Description
5