Function
Switch
Circuit
2 x SPDT
On-state Resistance
85 Ohm
Voltage Supply Source
Single, Dual Supply
Voltage - Supply, Single/dual (±)
9 V ~ 36 V, ±4.5 V ~ 18 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
16-SOIC (0.154", 3.90mm Width)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Figure 1. Simplified Internal Structure
The MAX4631/MAX4632/MAX4633 are fault-protected
analog switches with special operation and construc-
tion. Traditional fault-protected switches are construct-
ed using three series CMOS devices. This combination
produces good fault-protection but fairly high on-resis-
tance when the signals are within 3V of each supply
rail. These series devices are not capable of handling
signals up to the power-supply rails.
These devices differ considerably from traditional fault-
protection switches, with three advantages. First, they
are constructed with two parallel FETs, allowing very low
on-resistance when the switch is on. Second, they allow
signals on the NC_ or NO_ pins that are within or slightly
beyond the supply rails to be passed through the switch
to the COM_ terminal, allowing rail-to-rail signal opera-
tion. Third, when a signal on NC_ or NO_ exceeds the
supply rails by about 50mV (a fault condition), the volt-
age on COM_ is limited to the appropriate polarity sup-
ply voltage. Operation is identical for both fault
polarities. The fault-protection extends to ±25V
(MAX4632) or ±36V (MAX4631/MAX4633) with power
on and ±40V with power off.
The MAX4631/MAX4632/MAX4633 have a parallel N-
channel and P-channel MOSFET switch configuration with
NC_
NO_
_______________Detailed Description
or
INPUT
+15V
-15V
-15V
+15V
SWITCH
SWITCH
SENSE
SENSE
_______________________________________________________________________________________
N3
COMPARATOR
P3
COMPARATOR
P-CHANNEL
N-CHANNEL
DRIVER
DRIVER
N1
P1
+V (+15V)
-V (-15V)
CLAMP
CLAMP
Fault-Protected, High-Voltage,
N2
P2
OUTPUT COM_
input voltage sensors. The simplified structure is shown
in Figure 1. The parallel N1 and P1 MOSFETs form the
switch element. N3 and P3 are sensor elements to sam-
ple the input voltage and compare it against the power-
supply rails.
During normal operation of a conducting channel, N1
and P1 remain on with a typical 62Ω on-resistance
between NO_ (or NC_) and COM_. If the input voltage
exceeds either supply rail by about 50mV, the parallel
combination switches (N1, P1) are forced off through
the driver and sensing circuitry. At the same time, the
output (COM_) is clamped to the appropriate supply
rail by the clamp circuitry (N2, P2). Two clamp circuits
limit the output voltage to the supply voltages.
These switches have identical pinouts to common non-
fault-protected CMOS switches (DG401, DG403,
DG405). Exercise care in considering them as direct
replacements in existing printed circuit boards, since
only the NO_ and NC_ pins of each switch are fault pro-
tected.
Two comparators continuously compare the voltage on
the NO_ (or NC_) pin with V+ and V- supply voltages
(Figure 1). When the signal on NO_ (or NC_) is between
V+ and V-, the switch behaves normally, with FETs N1
and P1 turning on and off in response to NO_ (or NC_)
signals.
For any voltage between the supply rails, the switch is
bidirectional; therefore, COM_ and NO_ (or NC_) are
interchangeable. Only NO_ and NC_ can be exposed
to overvoltages beyond the supply range and within the
specified breakdown limits of the device.
The MAX4631/MAX4632/MAX4633 protect devices
connected to their outputs (COM_) through their unique
fault-protection circuitry. When the input voltage is
raised 50mV above either supply rail, the internal sense
and comparator circuitry (N3 and N-channel driver or
P3 and P-channel driver) disconnect the output (COM_)
from the input (Figure 1).
If the switch driven above the supply rail has an on
state, the clamp circuitry (N2 or P2) connects the out-
put to the appropriate supply rail. Table 1 summarizes
the switches’ operation under normal and fault conditions.
Dual Analog Switches
Normal Operation
Pin Compatibility
Fault Condition
9