G5V-1-9DC24 Omron, G5V-1-9DC24 Datasheet - Page 3

no-image

G5V-1-9DC24

Manufacturer Part Number
G5V-1-9DC24
Description
RELAY PC MNT SPDT 1A 24VDC
Manufacturer
Omron
Series
G5V-1r
Datasheet

Specifications of G5V-1-9DC24

Relay Type
General Purpose
Contact Form
SPDT (1 Form C)
Contact Rating (current)
1A
Switching Voltage
125VAC, 60VDC - Max
Coil Type
Non Latching
Coil Current
6.3mA
Coil Voltage
24VDC
Turn On Voltage (max)
19.2 VDC
Turn Off Voltage (min)
2.4 VDC
Features
Sealed - Fully
Mounting Type
Through Hole
Termination Style
PC Pin
Contact Material
Silver (Ag), Gold (Au)
Operate Time
5ms
Release Time
5ms
Coil Power
150 mW
Coil Resistance
3.84K Ohms
Operating Temperature
-40°C ~ 70°C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G5V19DC24
■ Characteristic Data
Dimensions
Note: 1. All units are in millimeters unless otherwise indicated. To convert millimeters into inches, multiply by 0.03937.
G5V-1
Precautions
Long-term Continuously ON Contacts
Using the Relay in a circuit where the Relay will be ON continuously
for long periods (without switching) can lead to unstable contacts,
because the heat generated by the coil itself will affect the insulation,
causing a film to develop on the contact surfaces. Be sure to use a
fail-safe circuit design that provides protection against contact failure
or coil burnout.
Maximum Switching Capacity
2. Numbers in parentheses are reference values.
3. Tolerance: ±0.1
4. Orientation marks are indicated as follows:
DC resistive load
Rated Operating voltage (V)
10 max.
(9.9)
3.5
AC
resistive
load
0.5
0.5
0.3
12.5 max.
(12.3)*
Electrical Service Life
5,000
3,000
1,000
700
500
300
100
0.3
70
50
125-VAC
resistive
load
Rated Operating current (A)
7.5 max.
(7.3)*
0.5
* Average value
24-VDC resistive load
Terminal Arrangement/
Internal Connections
(Bottom View)
Relay Handling
When washing the product after soldering the Relay to a PCB, use a
water-based solvent or alcohol-based solvent, and keep the solvent
temperature to less than 40°C. Do not put the Relay in a cold clean-
ing bath immediately after soldering.
1
10
2
9
Note: The maximum coil voltage refers to the maxi-
Low Signal Relay
5
6
Ambient Temperature vs.
Maximum Coil Voltage
Six, 1-dia. holes
mum value in a varying range of operating
power voltage, not a continuous voltage.
(1.07)
Ambient temperature (°C)
Mounting Holes
(Bottom View)
Rated coil voltage
2.54 7.62
10.16+0.1
G5V-1
5.08+0.1
(1.07)
(1.11)
(1.11)
47

Related parts for G5V-1-9DC24