G6SK-2FDC2 Omron, G6SK-2FDC2 Datasheet - Page 2

no-image

G6SK-2FDC2

Manufacturer Part Number
G6SK-2FDC2
Description
RELAY LOW SIGNAL LATCHING SMD
Manufacturer
Omron
Series
G6Sr

Specifications of G6SK-2FDC2

Relay Type
Telecom
Contact Form
DPDT (2 Form C)
Contact Rating (current)
2A
Switching Voltage
250VAC, 220VDC - Max
Coil Type
Latching, Dual Coil
Coil Current
100mA
Coil Voltage
2VDC
Turn On Voltage (max)
1.5 VDC
Turn Off Voltage (min)
-
Features
-
Mounting Type
Surface Mount
Termination Style
Gull Wing
Contact Material
Silver (Ag), Gold (Au)
Operate Time
4ms
Release Time
4ms
Coil Power
200 mW
Coil Resistance
20 Ohms
Operating Temperature
-40°C ~ 85°C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G6SK2FDC2
Construction
■ SEALING
Unsealed
Relays of this type are intended for manual soldering. No measures
are taken against penetration of flux and cleaning solvent into the
relay. This type of relay cannot be immersion-cleaned.
Semi-Sealed
Special design construction prevents flux from penetrating into the
relay housing, for example, due to capillary action up the terminals
when the relay is soldered onto a PCB. This type of relay also cannot
be immersion-cleaned.
2
Construction
Features
Automatic flux
application
Automatic soldering
Automatic cleaning
Manual soldering
Penetration of dust
Penetration of corrosive
gas
Construction
Features
Automatic flux
application
Automatic soldering
Automatic cleaning
Manual soldering
Penetration of dust
Penetration of corrosive
gas
Classification
Classification
Electromechanical Relays
Terminals are separated
from PCB surface when re-
lay is mounted.
Poor
Poor
Poor
Good
Fair
Poor
Terminals, base, and case are sealed.
Good
Good
Good
Good
Good
Fair
Terminals separated
from PCB
Press-fit terminals
Technical Information
Fully Sealed
Unsealed
Contacts are positioned
away from base.
Poor
Poor
Poor
Good
Resin seal
Contacts located at
upper part of relay case
Fully Sealed
Fully sealing prevents not only flux, but also cleaning solvent from
penetrating into the relay housing. Therefore, this type of relay can
be immersion-cleaned. Relays are each tested before being shipped.
The relay is immersed in fluorocarbon solution for 1 minute, at a tem-
perature of 70°C +5°C/-0°C, to see if gases escape from the relay.
The following figure illustrates the test conditions.
Terminals are pressed into
base.
Good
Good
Poor
Good
Fair
Poor
Terminal and base, as well as the base and casing, are
sealed.
Good
Good
Good
Good
Good
Fair
Terminals
separated
from PCB
Press-fit terminals
50 mm
Fluorocarbon
solution
Resin seal
Relay
Resin seal
Surface Mounting
Semi-Sealed
Terminals are inserted into
base 0.3 mm min. thick.
Good
Good
Poor
Good
Terminals
separated
from PCB
Ex.) 70 °C
Glue pad
Inserted terminals
0.3 mm
min. base
thickness

Related parts for G6SK-2FDC2