G6S-2G-10DC24 Omron, G6S-2G-10DC24 Datasheet - Page 10

no-image

G6S-2G-10DC24

Manufacturer Part Number
G6S-2G-10DC24
Description
RELAY LOW SIGNAL SMD
Manufacturer
Omron
Series
G6Sr

Specifications of G6S-2G-10DC24

Relay Type
Telecom
Contact Form
DPDT (2 Form C)
Contact Rating (current)
2A
Switching Voltage
250VAC, 220VDC - Max
Coil Type
Non Latching
Coil Current
8.3mA
Coil Voltage
24VDC
Turn On Voltage (max)
18 VDC
Turn Off Voltage (min)
2.4 VDC
Features
-
Mounting Type
Surface Mount
Termination Style
J Lead
Contact Material
Silver (Ag), Gold (Au)
Operate Time
4ms
Release Time
4ms
Coil Power
200 mW
Coil Resistance
2.88K Ohms
Operating Temperature
-40°C ~ 85°C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G6S2G10DC24
Precautions
• Use a DC power supply with 5% or less ripple factor to operate the coil.
• Do not use the G6S where subject to strong external magnetic fields.
• Do not use the G6S where subject to magnetic particles or excessive
• Do not reverse the polarity of the coil (+, −).
■ Correct use
Long-term Continuously ON Contacts
Using the Relay in a circuit where the Relay will be ON continuously
for long periods (without switching) can lead to unstable contacts
because the heat generated by the coil itself will affect the insulation,
causing a film to develop on the contact surfaces. We recommend
using a latching relay (magnetic-holding relay) in this kind of circuit. If
a single-side stable model must be used in this kind of circuit, we rec-
ommend using a fail-safe circuit design that provides protection
against contact failure or coil burnout.
Relay Handling
Use the Relay as soon as possible after opening the moisture-proof
package. If the Relay is left for a long time after opening the mois-
ture-proof package, the appearance may suffer and seal failure may
occur after the solder mounting process. To store the Relay after
opening the moisture-proof package, place it into the original pack-
age and sealed the package with adhesive tape.
When washing the product after soldering the Relay to a PCB, use a
water-based solvent or alcohol-based solvent, and keep the solvent
temperature to less than 40°C. Do not put the Relay in a cold clean-
ing bath immediately after soldering.
104
amounts of dust.
Low Signal Relay
G6S
• Latching types are delivered in the reset position. We recommend
• Do not drop the G6S or otherwise subject it to excessive shock.
• Remove the relay from the packing immediately prior to usage.
G6S (K) (-U) -2 Soldering
• Soldering temperature: Approx. 250°C (At 260°C if the DWS
• Soldering time: Approx. 5 s max. (Approx. 2 s for the first time and
• Be sure to adjust the level of the molten solder so that the solder
Claw Securing Force During Automatic Mounting
During automatic insertion of Relays, be sure to set the securing
force of each claw to the following so that the Relay’s characteristics
will be maintained.
Dimension A: 1.96 N max.
Dimension B: 4.90 N max.
Dimension C: 1.96 N max.
A
that a reset voltage be applied in advance to start operation.
method is used.)
approx. 3 s for the second time if the DWS method is used.)
will not overflow onto the PCB.
C
B

Related parts for G6S-2G-10DC24