G6KU-2F-RF-TR09DC5 Omron, G6KU-2F-RF-TR09DC5 Datasheet - Page 3

no-image

G6KU-2F-RF-TR09DC5

Manufacturer Part Number
G6KU-2F-RF-TR09DC5
Description
RELAY LOW SIGNAL HF SMD TR
Manufacturer
Omron
Series
G6K-RFr
Datasheet

Specifications of G6KU-2F-RF-TR09DC5

Relay Type
RF
Contact Form
DPDT (2 Form C)
Contact Rating (current)
1A
Switching Voltage
125VAC, 60VDC - Max
Coil Type
Latching, Single Coil
Coil Current
21.1mA
Coil Voltage
5VDC
Turn On Voltage (max)
3.75 VDC
Turn Off Voltage (min)
-
Features
-
Mounting Type
Surface Mount
Termination Style
Gull Wing
Contact Material
Silver (Ag), Gold (Au)
Operate Time
3ms
Release Time
3ms
Coil Power
100 mW
Coil Resistance
237 Ohms
Operating Temperature
-40°C ~ 70°C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G6KU2FRFTR09DC5
■ Characteristic data
Shock Malfunction
Maximum Switching Capacity
Shock direction
Electrical Service Life
Conditions:
DC resistive load
125 VAC resistive load
Ambient temperature: 23°C
Switching frequency:
1,800 operations/hour
Rated operating voltage (V)
Rated operating current (A)
Shock is applied in ±X, ±Y, and ±Z di
rections three times each with and with
out energizing the Relays to check the
number of contact malfunctions.
30 VDC resistive load
Ambient temperature: 23°C
Switching frequency:
1,800 operations/hour
AC resistive load
Not
energized
Unit: m/s
Sample: G6K-2G
Number of Relays: 10
Energized
2
Note: The maximum coil voltage refers to the maxi-
Electrical Service Life
(with Must Operate and Must
Release Voltage) (See note.)
G6K-2G (F/P), G6K-2G (F/P)-Y
Ambient Temperature vs.
Maximum Coil Voltage
Ambient Temperature vs. Must
Operate or Must Release Voltage
G6K-2G (F/P), G6K-2G (F/P)-Y
mum value in a varying range of operating
power voltage, not a continuous voltage.
Operating frequency (x10 operations)
Note: The tests were conducted at an
Must operate
Sample: G6K-2G
Number of Relays: 10
Test conditions: 1 A resistive load at
30 VDC with an operation rate of 50%
Switching frequency: 1,800 operations/h
Must release
ambient temperature of 23°C.
Ambient temperature (°C)
Ambient temperature (°C)
Max. estimated value
3
Operate voltage
Release voltage
Electrical Service Life
(Contact Resistance) (See note.)
G6K-2G (F/P), G6K-2G (F/P)-Y
Ambient Temperature vs.
Switching Current
Ambient Temperature vs. Must
Set or Must Reset Voltage
G6KU-2G (F/P)-Y
Low Signal Relay
Operating frequency (x10
Note: The tests were conducted at an
Switching frequency: 1,800 operations/h
Sample: G6K-2G
Number of Relays: 10
Test conditions: 1 A resistive load
at 30 VDC with an operation rate of 50%
Contact resistance
ambient temperature of 23°C.
Ambient temperature (°C)
Ambient temperature (°C)
Max. estimated value
G6K
3
operations)
NO
contact
NC
contact
69