HIH-6131-021-001 Honeywell Sensing and Control, HIH-6131-021-001 Datasheet

no-image

HIH-6131-021-001

Manufacturer Part Number
HIH-6131-021-001
Description
SENSOR HUMIDITY 3.3V 5% SMD
Manufacturer
Honeywell Sensing and Control

Specifications of HIH-6131-021-001

Mfg Application Notes
HIH-6130,6131 Medical, Industrial Appl
Output Type
I²C™
Sensor Type
Humidity and Temperature
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
480-3652-2
Honeywell HumidIcon™ Digital
Humidity/Temperature Sensors:
HIH-6130/6131 Series
GENERAL INFORMATION
The following associated literature is available on the Web:
SOLDERING AND ASSEMBLY
Sensing and Control
CAUTION
IMPROPER HANDLING
Failure to comply with these instructions may result in
product damage.
CAUTION
IMPROPER CLEANING
Failure to comply with these instructions may result in
product damage.
CAUTION
IMPROPER SENSOR POSITIONING
Failure to comply with these instructions may result in
product damage.
– Humidity Sensor Performance Characteristics
– Humidity Sensor Theory and Behavior
– Humidity Sensor Moisture and Psychrometrics
– Humidity Sensor Chemical Resistivity
– Thermoset Polymer-based Capacitive Sensors
– I
– Using Alarms on the Honeywell HumidIcon™ Digital
– Entering and Using Command Mode on the Honeywell
– Total Error Band Specification for Honeywell Digital
Product data sheet
Product application note
Application sheets:
Technical Notes:
Insert and solder the sensor after the PCB cleaning
process.
Position the sensor so that its face is exposed to the
atmosphere being monitored.
Do not remove the sensor from its original protective
packaging until it is ready to be installed.
Do not touch the sensor surface. Use latex finger cots.
Handle the sensor by its package edges or leads.
Do not allow objects to enter the cavity of the sensor
element.
Do not allow debris or contaminants to accumulate on
the filter.
Digital Humidity/Temperature Sensors: HIH-6130/6131
Series
Humidity/Temperature Sensors: HIH-6130/6131 Series
HumidIcon™ Digital Humidity/Temperature Sensors:
HIH-6130/6131 Series
Humidity/Temperature Sensors
2
C Communication with the Honeywell HumidIcon™
PROTECTIVE TAPE REMOVAL
1.
2.
3.
Figure 1. Protective Tape Removal
SOLDERING
Process
CAUTION
IMPROPER SOLDERING
Failure to comply with these instructions may result in
product damage.
For better product reliability, the HIH-6130/6131 Series is
factory-shipped with a protective tape on the cover
(sensing face). This tape must remain in place during
soldering.
After soldering, remove the protective tape as described
below to activate the sensor.
Use proper ESD protection.
Using covered fingers or tweezers to ensure that no debris
falls into the filter, sensor cover or die, grip the
overhanging front edge of the protective tape and peel it
back from the top surface of the sensor.
Ensure the complete rectangle of protective tape is
removed.
Automated: Use a no-clean flux. Limit the contact of the
flux to the leads only. Reflow soldering profile is specified
by J-STD-020D for a small package with a peak
temperature of 260 C [500 F].
Manual: Do not exceed 350 C [662 F] for
4 s max.

Related parts for HIH-6131-021-001

HIH-6131-021-001 Summary of contents

Page 1

... Failure to comply with these instructions may result in product damage. Sensing and Control CAUTION IMPROPER SOLDERING For better product reliability, the HIH-6130/6131 Series is factory-shipped with a protective tape on the cover (sensing face). This tape must remain in place during soldering. After soldering, remove the protective tape as described below to activate the sensor ...

Page 2

... HIH-6130/6131 Series SENSOR REHYDRATION NOTICE SENSOR REHYDRATION Exposure to elevated temperatures, such as those experienced during solder reflow, may dry out the sensing element recommended that the sensor be allowed time to rehydrate after soldering or other high temperature/dry exposures. Exposure to these conditions will not permanently damage the sensor ...

Page 3

... HIH-6130/6131 Series Table 3. Temperature Performance Specifications Characteristic Supply voltage variation Compensated temp. range Resolution 1 Accuracy (BFSL) Response time Long term stability Impact of soldering IPC/EIA/JEDEC J-STD-020D, peak temp. Note: 1. Accuracy is specified over the compensated temperature range. Table 4. Current Consumption Characteristic V DD Sleep current 3 ...

Page 4

... HIH-6130/6131 Series Figure 3. Mounting Dimensions and Pinout (For reference only. mm/[in]) Pin ASIC Pad 1 V CORE SCL 4 SDA 1 5 AL_H 1 6 AL_L Note not connect Pin(s) 5 and/ the built-in alarm feature is not desired. Figure 5. Tape and Reel Dimensions (For reference only. mm/[in]) (Note: Shown with tape cover removed ...

Page 5

... HIH-6130/6131 Series Figure 6. Typical Application Circuit V = 2.3 Vdc to 5.5 Vdc SUPPLY 0.22 µF 0.1 µF GND Figure 7. HIH-6130/6131 Series Maximal Accuracy 90 ±1 ±1 80 ±1 ±2 70 ±2 ±2 60 ±2 ±2 50 ±2 ±2 40 ±2 ±2 30 ±2 ±2 20 ±1 ±1 10 ±1 0 Note: 1. Maximal accuracy is the mean value between rising and falling RH points. ...

Page 6

... HIH-6130/6131 Series WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. The sensor’s housing does not provide electrical safety isolation. Mount the sensor in a location where it cannot be touched, or where a surrounding barrier prevents human contact ...