2302-PJ KEITHLEY, 2302-PJ Datasheet - Page 2

58T8418

2302-PJ

Manufacturer Part Number
2302-PJ
Description
58T8418
Manufacturer
KEITHLEY
Datasheet

Specifications of 2302-PJ

No. Of Outputs
1
Output Voltage
15V
Output Current
5A
Load Regulation
0.01%
Length
411mm
Width
213mm
Height
89mm
Weight
3.2kg
Power Supply Output Type
Variable
Input Voltage
100VAC To 120VAC / 220VAC To 240VAC
Power Rating
60W
2302-PJ Battery Simulator
ISOLATION (low–earth): 22VDC max. Do not exceed 60VDC between any two ter-
PROGRAMMING: IEEE-488.2 (SCPI).
USER-DEFINABLE POWER-UP STATES: 4.
REAR PANEL CONNECTORS: 8-position quick disconnect terminal block for out-
TEMPERATURE COEFFICIENT (outside 23°C ±5°C): Derate accuracy specification
OPERATING TEMPERATURE: 0° to 50°C (Derate to 70%). 0° to 35°C (Full power).
STORAGE TEMPERATURE: –20° to 70°C.
HUMIDITY: <80% @ 35°C non-condensing.
DISPLAY TYPE: 2-line 16 character VFD.
REMOTE DISPLAY/KEYPAD OPTION: Disables standard front panel.
DIMENSIONS: 89mm high 213mm wide 411mm deep (3
NET WEIGHT: 3.2kg (7.1 lbs).
SHIPPING WEIGHT: 5.4kg (12 lbs).
INPUT POWER: 100–120VAC/220–240VAC, 50 or 60Hz (auto detected at power-up).
POWER CONSUMPTION: 150VA max.
WARRANTY: Two years parts and labor on materials and workmanship.
EMC: Conforms with European Union Directive directive 89/336/EEC.
SAFETY: Conforms with European Union Directive 73/23/EEC.
AC LINE LEAKAGE CURRENT: 450µA @ 110VAC, typ.; 600µA @ 220V, typ.
RELAY CONTROL PORT: 4-channel, each capable of 100mA sink, 24V max. Total
ACCESSORIES SUPPLIED: User and service manual, output connectors mating
ACCESSORIES AVAILABLE:
minals of either connector.
put (4), sense (2), and DVM (2).
by (0.1 specification)/°C.
port sink capacity (all 4 combined) is 250mA max. Accepts DB-9 male plug.
terminal (part no. CS-846).
Model 2304-DISP: Remote LCD Display/Keypad (4.6 in 2.7 in 1.5 in). Includes
2.7m (9 ft) cable and rack mount kit.
GENERAL
1
2
in 8
3
8
in 16
3
16
in).
1
2
3
4
5
6
7
8
9
10
11
12
13
Specifications are subject to change without notice.
PLC = 1.00.
Following 15 minute warm-up, the change in output over 8 hours under ambient temper-
ature, constant load, and line operating conditions.
Remote sense, at output terminals, 0.5A to 5A typical.
Remote sense, with 4.5m (15 ft) of 16 gauge (1.31mm
to simulate typical test environment, 1.5A load change (0.15A to 1.65A).
Minimum current in constant current mode is 6mA.
60Hz (50Hz).
PLC = Power Line Cycle. 1PLC = 16.7ms for 60Hz operation, 20ms for 50Hz operation.
Display off.
Speed includes measurement and binary data transfer out of GPIB.
Typical values, peak-to-peak noise equals 6 times rms noise.
Based on settled signal: 100µs pulse trigger delay.
Also applies to other apertures that are integer multiples of 1PLC.
Recovery to within 20mV of previous level.
2
) wire and 1 resistance in each lead
HW 6/27/02
Rev. A

Related parts for 2302-PJ