CY7C0852V-150BBC Cypress Semiconductor Corp, CY7C0852V-150BBC Datasheet - Page 14

no-image

CY7C0852V-150BBC

Manufacturer Part Number
CY7C0852V-150BBC
Description
Manufacturer
Cypress Semiconductor Corp
Datasheets

Specifications of CY7C0852V-150BBC

Density
4Mb
Access Time (max)
4ns
Operating Supply Voltage (typ)
3.3V
Package Type
BGA
Operating Temp Range
0C to 70C
Supply Current
450mA
Operating Supply Voltage (min)
3.135V
Operating Supply Voltage (max)
3.465V
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
172
Word Size
36b
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CY7C0852V-150BBC
Manufacturer:
CY
Quantity:
19
Part Number:
CY7C0852V-150BBC
Manufacturer:
CY
Quantity:
25
Document #: 38-06059 Rev. *D
CLAMP
The optional CLAMP instruction allows the state of the signals
driven from CY7C0851V/CY7C0852V/CY7C0853V pins to be
determined from the boundary-scan register while the
BYPASS register is selected as the serial path between TDI
and TDO. CLAMP controls boundary cells to 1 or 0.
NBSRST
This is the Non-Boundary Scan Reset instruction. NBSRST
places the Bypass Register (BYR) between TDI and TDO
when selected. Its function is to reset every logic (similar to
MRST) except that it does not reset the JTAG logic.
Boundary Scan Cells (BSC)
Every CY7C0851V/CY7C0852V/CY7C0853V output has two
boundary scan cells; one for data, and one for three-state
Notes:
16. I
17. The “0”/”1” next to each state represents the value at TMS at the rising edge of CLK.
1
0
SB3
values only if JTAG pins are not active and mpdaster reset (MRST) not enabled.
RUN_TEST/
IDLE
TEST-LOGIC
RESET
0
1
Figure 3. TAP Controller State Diagram (FSM)
1
0
PRELIMINARY
SELECT
DR-SCAN
CAPTURE-DR
SHIFT-DR
EXIT1-DR
PAUSE-DR
EXIT2-DR
UPDATE-DR
1
0
1
0
1
1
0
[15]
CY7C0851V/CY7C0852V/CY7C0853V
control. JTAG TAP pins (TDI, TMS, TDO, TCK), MRST, and all
power and ground pins have no scan cell. Other
CY7C0851V/CY7C0852V/CY7C0853V inputs have only the
data scan cell.
Active and Standby Supply Current
When the instruction in the JTAG instruction register selects
the Boundary Scan Register (BSR) and the TAP controller is
in any state except TEST-LOGIC-RESET or RUN-TEST/IDLE,
then the device supply current (I
With the JTAG logic in this state, and both ports inactive with
CMOS input levels, it is possible for the supply current to
exceed the ISB3 value given in the Electrical Characteristics
section of this data sheet.
0
0
1
0
1
CY7C0831V/CY7C0832V
[17]
1
0
CAPTURE-IR
SHIFT-IR
EXIT1-IR
PAUSE-IR
EXIT2-IR
UPDATE-IR
SELECT
IR-SCAN
1
CC
or I
0
0
1
1
1
0
[16]
SB1/2/3/4
0
Page 14 of 33
) will increase.
1
0
1
0