LC04-12 Semtech, LC04-12 Datasheet - Page 4

LC04-12

Manufacturer Part Number
LC04-12
Description
Manufacturer
Semtech
Datasheet

Specifications of LC04-12

Number Of Elements
4
Polarity
Uni-Directional
Package Type
SOIC
Operating Temperature Classification
Military
Reverse Breakdown Voltage
13.3V
Clamping Voltage
24V
Reverse Stand-off Voltage
12V
Leakage Current (max)
2uA
Peak Pulse Current
100A
Peak Pulse Power Dissipation
600W
Test Current (it)
1mA
Operating Temp Range
-55C to 125C
Mounting
Surface Mount
Pin Count
16
Lead Free Status / Rohs Status
Not Compliant
Device Connection Options
The LC04-12 is designed to protect up to four high-
speed data lines (two differential pairs) from transient
over-voltages which result from lightning and ESD.
Differential protection of two line pairs is achieved by
connecting the device as follows (Figure 1): Pins 1-4
are connected to line 1 of the first pair (i.e. Tip 1) and
pins 13-16 are connected to line 2 of the first pair (i.e.
Ring 1). Pins 5-8 are connected to line 1 of the second
pair (i.e. Tip 2) and pins 9-12 are connected to line 2 of
the second pair (i.e. Ring 2).
Common mode protection of one line pair is achieved
by connecting the device as shown in Figure 2. The
protected lines are connected at pins 1-4 and pins 9-
12. connection to ground is made at pins 5-8 and 13-
16. optionally, the lines may be connected at pins 1-4
and 5-8 with pins 9-16 being connected to ground.
All pins should be connected for best results. Minimize
parasitic inductance in the protection circuit path by
keeping the trace length between the protected line
and the LC04-12 as short as possible. Ground con-
nections should be made directly to the ground plane.
ADSL Protection
Configuring The LC04-12 for Remote Terminal ADSL
Applications
A typical ADSL protection circuit for remote terminals is
shown in Figure 3. The LC04-12 is connected between
Tip & Ring on the transmit and receive line pairs. It
provides protection to common mode (line-to-ground)
lightning and ESD surges. It is designed to meet the
intra-building requirements of Bellcore GR-1089. To
complete the protection circuit, the LCDA12C-1 is
employed as the IC side protection element. This
device helps prevent the transceiver from latching up
by providing fine clamping of transients that are
coupled through the transformer.
PROTECTION PRODUCTS
Applications Information
2003 Semtech Corp.
4
Figure 1 - Connection for Differential (Line-to-Line)
Figure 2 - Connection for Common Mode (Line-to-
TIP 1
TIP 2
Ground) Protection of one Tip/Ring Line Pair
GND
TIP
Protection of two Tip/Ring Line Pairs
LC04-12
www.semtech.com
RING 1
RING 2
GND
RING