LM235H National Semiconductor, LM235H Datasheet - Page 13

LM235H

Manufacturer Part Number
LM235H
Description
Manufacturer
National Semiconductor
Datasheet

Specifications of LM235H

Temperature Sensor Function
Temp Sensor
Output Type
Analog
Operating Temperature (min)
-40C
Operating Temperature (max)
125C
Operating Temperature Classification
Automotive
Operating Supply Voltage (min)
5V
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM235H
Manufacturer:
NSC
Quantity:
15
Part Number:
LM235H
Manufacturer:
NS/国半
Quantity:
20 000
Part Number:
LM235H/NOPB
Manufacturer:
ST
0
*Self heating is used to detect air flow
DEFINITION OF TERMS
Operating Output Voltage: The voltage appearing across
the positive and negative terminals of the device at specified
conditions of operating temperature and current.
Uncalibrated Temperature Error: The error between the
operating output voltage at 10 mV/°K and case temperature
at specified conditions of current and case temperature.
Ground Referred Centigrade Thermometer
Air Flow Detector*
13
Calibrated Temperature Error: The error between operating
output voltage and case temperature at 10 mV/°K over a tem-
perature range at a specified operating current with the 25°C
error adjusted to zero.
569816
569817
www.national.com