HIGH FREQUENCY CHARACTERISTICS (Impedance 50) Frequency V.S.W.R. (max.) V.S.W.R. (SP6T With termination) (max.) Insertion loss (dB. max.) Isolation (dB. min.) Notes: *1The 6GHz type only has the above characteristics up to 6GHz. *218 to 26.5GHz characteristics can be ...
Page 2
... ARD60012Q ARD60024 ARD60024Q ARD6204H ARD6204HQ ARD62012 ARD62012Q ARD62024 ARD62024Q ARD65105 ARD65105Q ARD65112 ARD65112Q ARD65124 ARD65124Q 13GHz type HF datasheet attached ARD3004HQ ARD30012Q ARD30024Q ARD3204HQ ARD32012Q ARD32024Q ds_61309_en_rd: 010709J HF datasheet attached ARD5004HQ ARD50012Q ARD50024Q ARD5204HQ ARD52012Q ARD52024Q ARD55105Q ARD55112Q ARD55124Q — — — ...
Page 3
SP6T (with termination) Nominal operating Operating function voltage 4.5 Fail-safe 12 24 4.5 Latching 12 24 Note: Standard packing; Carton: 1 pc. Case: 5 pcs. RATING 1. Coil data (1) SPDT 1) Fail-safe type Nominal operating current, ...
Page 4
RD (ARD) • Operating voltage range 1) Fail-safe type Nominal voltage Allowable range 2. for use Recommended ...
Page 5
Specifications 1) SPDT/Transfer Characteristics Item Arrangement Contact Contact material Initial contact resistance Contact input power Rating Fail-safe Nominal operating Latching power Contact rating Indicator rating (with Initial contact resistance indicator type only) Min. switching capacity (Reference value) High frequency ...
Page 6
RD (ARD) 2) SP6T Characteristics Item Arrangement Contact Contact material Initial contact resistance No termination Contact input power With termination Rating Nominal Fail-safe operating Latching power Contact rating Initial contact resistance Indicator rating Min. switching capacity (Reference value) No termination ...
Page 7
REFERENCE DATA 1-(1). High frequency characteristics (SPDT) 6GHz type Sample: ARD70012 Measuring method: Measured with Agilent Technologies network analyzer (E8363B). • V.S.W.R. 1.9 1.8 1.7 1.6 1.5 1.4 Standard value 1.3 Reference value 1.2 1.1 1.0 30MHz 1GHz 4GHz 6GHz ...
Page 8
RD (ARD) 1-(4). High frequency characteristics (SP6T) Sample: ARD30012 Measuring method: Measured with Agilent Technologies network analyzer (HP8510). • V.S.W.R. 2.0 1.9 1.8 1.7 1.6 1.5 Standard value 1.4 1.3 Reference value 1.2 1.1 1.0 1GHz 4GHz 8GHz 13GHz 18GHz ...
Page 9
... Indicator Coil GND + Serial No. + COM type is available * The type without indicator terminals will not have the indicator terminals that are marked with the dotted box. ds_61309_en_rd: 010709J your local Panasonic Electric Works representative. 11.2 .441 3.5 .138 3.5 4.3 .138 ...
Page 10
RD (ARD) 2) Connector cable Fail-safe NC COM NO Indicator terminal Coil terminal GND + COM type is available 10 Pin No. 1 Fail-safe – Latching – Latching with – TTL driver D-sub connector pin contact type 1 2345 ...
Page 11
Transfer CAD Data Fail-safe Coil terminal Indicator terminal GND + COM type is available ds_61309_en_rd: 010709J 45.70 1.799 15.24 .600 0.30 .012 3-3.80 dia. 3-.150 dia. Indicator Coil NC GND + COM NO 20.3 .799 Serial No. J1 ...
Page 12
RD (ARD) 3. SP6T CAD Data Fail-safe type Coil terminal GND Indicator terminal COM COM COM Indicator terminal Coil terminal GND ...
Page 13
SP6T (with termination) CAD Data Fail-safe type Coil terminal GND Indicator terminal COM COM COM Indicator terminal Coil terminal GND ...
Page 14
RD (ARD) NOTES 1. For general cautions for use, please refer to the “General Application Guidelines”. 2. Coil operating power Pure DC current should be applied to the coil. The wave form should be rectangular includes ripple, the ...