G6B-1177P-ND-USDC24 Omron, G6B-1177P-ND-USDC24 Datasheet - Page 4

no-image

G6B-1177P-ND-USDC24

Manufacturer Part Number
G6B-1177P-ND-USDC24
Description
RELAY PWR SPST-NO PCB
Manufacturer
Omron
Series
G6Br
Datasheet

Specifications of G6B-1177P-ND-USDC24

Relay Type
General Purpose
Contact Form
SPST-NO (1 Form A)
Contact Rating (current)
8A
Switching Voltage
380VAC, 125VDC - Max
Coil Type
Non Latching
Coil Current
8.3mA
Coil Voltage
24VDC
Turn On Voltage (max)
16.8 VDC
Turn Off Voltage (min)
2.4 VDC
Features
Sealed - Flux Protection
Mounting Type
Through Hole
Termination Style
PC Pin
Contact Material
Silver Alloy, Cadmium Free
Operate Time
10ms
Release Time
10ms
Coil Power
200 mW
Coil Resistance
2.88K Ohms
Operating Temperature
-25°C ~ 70°C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G6B 1304E
G6B-1177P-US-DC24
G6B-1177P-USDC24
G6B1177PNDUS24DC
G6B1177PNDUSDC24
Z3298
■ Approved Standards
UL Recognized (File No. E41643) / CSA Certified (File No. LR31928)
Engineering Data
152
G6B-1114P-US
G6B-1114C-US
G6BU-1114P-US
G6BU-1114C-US
G6BK-1114C-US
G6BK-1114C-US
G6B-1174P-US
G6B-1174C-US
G6B-2114P-US
G6B-2114C-US
G6B-2214P-US
G6B-2214C-US
G6B-2014P-US
G6B-2014C-US
G6B-1114P-US
Maximum Switching Capacity
G6B-2114P-US, G6B-2214P-US, G6B-2014P-US
Maximum Switching Capacity
DC inductive load
(L/R = 7 ms)
DC inductive load
(L/R = 7 ms)
DC resistive load
AC inductive load
(cosφ = 0.4)
DC resistive load
Switching voltage (V)
AC inductive load
(cosφ = 0.4)
Switching voltage (V)
Power PCB Relay
Model
AC resistive load
AC resistive
load
G6B
SPST-NO
SPST-NO + SPST-NC
DPST-NO
DPST-NC
Electrical Service Life
Electrical Service Life
Contact form
250 VAC inductive load (cosφ = 0.4)
30 VDC inductive load (L/R = 7 ms)
G6B-1114P(C)-US
250 VAC/30 VDC
inductive load
(cosφ = 0.4, L/R = 7 ms)
Switching current (A)
G6B-1114P(C)-US
250 VAC/30 VDC resistive load
250 VAC resistive load
30 VDC resistive load
Switching current (A)
G6B-1174P(C)-US
250 VAC/30 VDC
resistive load
3 to 24 VDC
Coil rating
Note: The maximum coil voltage refers
Ambient Temperature vs.
Maximum Coil Voltage
to the maxi-mum value in a
varying range of operating power
voltage, not a continuous voltage.
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
5 A at 250 VAC (General Use) 80°C
5 A at 30 VDC (Resistive) 80°C
8 A at 250 VAC (General Use) 80°C
8 A at 30 VDC (Resistive) 80°C
5 A at 250 VAC (general use) 40°C
5 A at 30 VDC (resistive load) 40°C
Ambient temperature (°C)
G6B-1174P-US
G6B-1114P-US
Contact rating