IC TXRX T1 1-CHIP 5V LP 44-PLCC

DS2151Q/T&R

Manufacturer Part Number
DS2151Q/T&R
Description
IC TXRX T1 1-CHIP 5V LP 44-PLCC
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS2151Q/T&R

Function
Single-Chip Transceiver
Interface
T1
Number Of Circuits
1
Voltage - Supply
4.75 V ~ 5.25 V
Current - Supply
65mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
44-LCC, 44-PLCC
Includes
Alarm Detector and Generator, CSU Loop Codes Generator and Detector, DSX-1 and CSU Line Build-Outs Generator
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Power (watts)
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS2151Q/T&RDS2151Q/T&R
Manufacturer:
Maxim Integrated
Quantity:
10 000
SR1: STATUS REGISTER 1 (Address = 20 Hex)
(MSB)
LUP
SYMBOL
RSLIP
LOTC
RYEL
RLOS
LDN
RBL
RCL
LUP
LDN
POSITION
SR1.7
SR1.6
SR1.5
SR1.4
SR1.3
SR1.2
SR1.1
SR1.0
LOTC
NAME AND DESCRIPTION
Loop Up Code Detected. Set when the repeating ...00001...
loop up code is being received.
Loop Down Code Detected. Set when the repeating ...001...
loop down code is being received.
Loss of Transmit Clock. Set when the TCLK pin has not
transitioned for one channel time (or 5.2Ps). Will force pin 16
high if enabled via CCR1.6. Based on RCLK.
Receive Elastic Store Slip Occurrence. Set when the receive
elastic store has either repeated or deleted a frame.
Receive Blue Alarm. Set when a blue alarm is received at
RTIP and RRING. See note below.
Receive Yellow Alarm. Set when a yellow alarm is received at
RTIP and RRING.
Receive Carrier Loss. Set when 192 consecutive 0s have been
detected at RTIP and RRING.
Receive Loss of Sync. Set when the device is not synchronized
to the receive T1 stream.
RSLIP
22 of 60
RBL
RYEL
RCL
(LSB)
RLOS
DS2151Q