FARM2C11 Vicor Corporation, FARM2C11 Datasheet
FARM2C11
Available stocks
Related parts for FARM2C11
FARM2C11 Summary of contents
Page 1
RoHS compliant (with pin style) • EMI filtering • Choice of 500 W or 750 W modules • 96% efficiency • Autoranging 115/230 Vac input • Microprocessor controlled • Inrush current limiting • Mini sized package • ...
Page 2
Electrical characteristics apply over the full operating range of input voltage, output power and baseplate temperature, unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate. Specifications apply for AC mains having up to ...
Page 3
SAFETY SPECIFICATIONS (FARM1xxx, FARM2xxx) Parameter Min Isolation voltage (in to out) Dielectric withstand 2,121 (I/O to baseplate) Leakage current AGENCY APPROVALS Safety Standards FARM1 xxx UL60950, EN60950, CSA 60950 FARM2 xxx UL60950, EN60950, CSA 60950 GENERAL SPECIFICATIONS Parameter MTBF Baseplate ...
Page 4
Vdc output Strap Engaged Enable B OK Figure 1 — Start up at 120 Vac input I ac input @ Enable B OK Figure 3 — Power down, from 120 Vac Vdc output Figure 5 — Output ...
Page 5
The Filtered, Autoranging Rectifier Module (FARM) provides an effective solution for the AC frontend of a power supply built with Vicor DC-DC converters. This high-performance power system building block satisfies a broad spectrum of requirements and agency standards. In addition ...
Page 6
The FARM maintains the DC output bus voltage between 250 and 370 Vdc over the entire input voltage range, which is compatible with Vicor 300 V input converters. The FARM automatically switches to the proper bridge or doubler mode depending ...
Page 7
Not used with VI-260/VI-J60 Vdc BOK EMI GND 150 k ST FARM N/C EN Micro- controller – L Figure 10 — Enable (EN) function + N +5 Vdc 15 Vdc BOK EMI GND Secondary ST referenced N/C ...
Page 8
The power fail warning time (Δt) is defined as the interval between B OK and converter shut down (EN) as illustrated in Fig. 13. The Bus-OK and Enable thresholds are 205 V and 190 V, respectively. A simplified relationship between ...
Page 9
Ripple (V p-p) Figure 13 — Hold-up time 250 500 Operating Power (W) Figure 14 — Power fail warning time vs. operating power and total bus capacitance, series combination of C1, ...
Page 10
Converter Pins No. Function Label 1 Neutral N 2 EMI GND 3 NC 0.23 4 Line L (REF) 5,8 5 –Out – 0.300 ±0.015 6 Enable EN 7,62 ±0,38 7 Strap ST 8 BUS OK BOK 0.300 ±0.015 7,62 ±0,38 ...
Page 11
Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal use and service. This warranty does not extend to products subjected to misuse, accident, or improper application or maintenance. Vicor ...