VI-AIM-E1 Vicor Corporation, VI-AIM-E1 Datasheet
VI-AIM-E1
Available stocks
Related parts for VI-AIM-E1
VI-AIM-E1 Summary of contents
Page 1
... Baseplate-to-sink °C M-Grade °C M-Grade EN61000-4-5 IEC 801-5 With external MOV Notes Used with a 100 – 200 Vin converter Used with a 200 – 400 Vin converter Used with a 100 – 375 Vin converter Input Module Operating Storage - - 100 100 ...
Page 2
... VDE 0871/FCC Part 15, Class A Conducted EMI/RFI UL1950, CSA 22.2-950, EN60950 GENERAL SPECIFICATIONS Parameter Min Size 2.28" x 2.4" x 0.5" (57,9 x 61,0 x 12,7) Weight Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Set your site on VICOR at vicorpower.com Typ Max Unit 1 85 – 264 Vac 47 – 440 ...
Page 3
... Z1 0.47 µF [a] Consult factory or refer to Selecting Capacitors for AIM Modules on page 34 of the VI-200 and VI-J00 Design Guide . Z1: MOV Part #30076 Fuse 1: 6.3A/250V (IEC 5X20 mm) Buss GDB-6 250 V (3AG 1/4" 1/4") Littlefuse 314-007 Fuse 2: For VI-X7X-XX — Buss PC-Tron 2.5 A (250 V) For VI-X6X-XX — ...
Page 4
... Vicor does not assume any liability arising out of the application or use of any product or circuit; neither does it convey any license under its patent rights nor the rights of others. Vicor general policy does not recommend the use of its components in life support applications wherein a failure or malfunction may directly threaten life or injury. Per Vicor Terms and Conditions of Sale, the user of Vicor components in life support applications assumes all risks of such use and indemnifies Vicor against all damages ...