MI-AIM-M1 Vicor Corporation, MI-AIM-M1 Datasheet
MI-AIM-M1
Related parts for MI-AIM-M1
MI-AIM-M1 Summary of contents
Page 1
... Spikes Parameter Min Typ Output power 250 Hold-up time Application specific Efficiency 95% Model Number Compatible MI-Series Converter MI-AIM-M1 MI-27x /MI-J7x M–grade MI-AIM-I1 MI-27x /MI-J7x I–grade MI-AIM, AC Input Front End Module Actual size: 2.28 x 2.4 x 0.5 in 57,9 x 61,0 x 12,7 mm Max Unit Notes ...
Page 2
... Altitude - Method 500.2 70,000 Humidity - Method 507.2 88/ 240 Acceleration - Method 513.3 9.0 Vibration - Method 514.3 20 Shock - Method 516.3 40 RELIABILITY — MIL-HDBK-217F (MI-AIM-M1) Parameter Min 25°C Ground Benign: G.B. 50°C Naval Sheltered: N.S. 65°C Airborne Inhabited Cargo: A.I.C. GENERAL SPECIFICATIONS Parameter Min Size ...
Page 3
... Explosive Atmosphere MIL-STD-810C, Method 511.1, Procedure I MIL-STD-810D, Method 514.3, Procedure I, category 6, helicopter MIL-STD-810D, Method 514.3 random: 10 – 300 /Hz, 2000 Hz @ 0.002 Hz, 3.9 total G rms Vibration /axis. Sine 6.6 g, 120 Hz @ 5.0 g, 16.0 total G rms, 3 axes MIL-STD-810E, Method 514.4, Table 514.4-VII, ±6 db/octave, 7.7 G rms, 1hr/axis MIL-STD-810D, Method 516 ...
Page 4
... 0.47 µF N/C L2/N [b] 1,200 µF max. Fuse 1: 7A F03A type recommended Fuse 2: MI-x7x-xx – Buss PC – TRON 2 – (450 V) Figure 1 — MI-AIM Connection diagram, typical application in (57,9) (mm) .49 (12,4) .65 .30±.015 (16,5) (7,6)±(0,38 2.10 MI-AIM VI-AIM ...
Page 5
... Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal use and service. This warranty does not extend to products subjected to misuse, accident, or improper application or maintenance. Vicor shall not be liable for collateral or consequential damage. This warranty is extended to the original purchaser only ...