V300A28C500BF2 Vicor Corporation, V300A28C500BF2 Datasheet - Page 3

no-image

V300A28C500BF2

Manufacturer Part Number
V300A28C500BF2
Description
Manufacturer
Vicor Corporation
Datasheet
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
Note:
Specifications are subject to change without notice.
PC bias voltage
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
Remote sense (total drop)
Isolation voltage
Isolation resistance (in to out)
Weight
Temperature limiting
Agency approvals
in to out
in to base
out to base
current limit
(PC = Primary Control; PR = Parallel)
(SC = Secondary Control)
(209.3)
Set your site on VICOR at vicorpower.com
3000
1500
5.50
1.21
150
375
990
500
100
1.5
2.3
0.9
5.7
2.4
7.4
cURus, TÜV, CE
(232.5)
0.033
1000
5.75
1.23
500
115
2.1
2.6
1.0
5.9
2.5
8.2
10
4
0
(255.7)
1010
6.00
1.24
625
3.0
2.9
0.5
1.1
6.1
2.6
0.5
9.0
12
7
300V Maxi Family
modules
(grams)
ounces
Vrms
Vrms
Vrms
Vavg
Volts
Volts
Vdc
Vdc
Vdc
Vdc
Vdc
mA
mA
ms
µF
°C
Ω
Ω
PC current = 1.0 mA
PC voltage = 5.5 V
Must be able to sink ≥4 mA. See Fig. 1
UV, OT, module fault. See Figs. 2 and 4
See Fig. 2
PR load >30 Ω, < 30 pF
25°C
Minimum pulse width: 20 ns
Without PR buffer amplifier
Referenced to –Sense
With open trim; referenced to –Sense. See Fig. 6
0.25 V per leg (senses must be closed)
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
See Figs. 2 and 4
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Rev. 8.7
Page 3 of 13