BXA40-48S05-MJ Astec Power, BXA40-48S05-MJ Datasheet
BXA40-48S05-MJ
Related parts for BXA40-48S05-MJ
BXA40-48S05-MJ Summary of contents
Page 1
... The series offers two wide input voltage ranges, 18 Vdc to 36 Vdc and 36 Vdc to 75 Vdc, and is available with single outputs from 2 The BXA40 series is designed to meet ETSI telecoms interface standards ETS300-132-2. Together with internal filtering, safety approval to IEC950 and basic insulation, the 48 V models are ideal for telecommunications applications ...
Page 2
... EN60950, UL1950 CSA C22.2 No. 950 Aluminum substrate with plastic case UL94V (3.0 oz) MIL-HDBK-217F 500,000 hours 2.2 x 2.2 x 0.5 inches 55.9 x 55.9 x 12.7 mm Baseplate operating -40 °C to +105 °C temperature Non-operating -55 °C to +105 °C No air flow, no heatsink 8.5 °C/W No air flow, with heatsink 7.2 °C/W Rev.03.08.07 bxa40s ...
Page 3
... No Connection - Sense (8) + Sense (8) + Output Common Trim Embedded Power for Business-Critical Continuity REGULATION MODEL LINE LOAD NUMBER (2) (3) (12,14,15) 0.3% 1.0% BXA40-24S3V3-SMJ 0.3% 1.0% BXA40-24S05-MJ 0.3% 1.0% BXA40-48S2V9-SMJ 0.3% 1.0% BXA40-48S05-MJ 0.3% 1.0% BXA40-48S12-MJ ° C baseplate temp TRIM DOWN RT1 9 9 10KΩ OR TRIMPOT RT2 TRIM Rev.03.08.07 bxa40s (8) (8) (8) (8) ...
Page 4
... Connectivity DC Power Embedded Power Inbound Power Integrated Cabinet Solutions Outside Plant Precision Cooling Site Monitoring and Services EmersonNetworkPower. com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2007 Emerson Electric Co. Rev.03.08.07 bxa40s ...