AT89C51RC Atmel Corporation, AT89C51RC Datasheet - Page 22

no-image

AT89C51RC

Manufacturer Part Number
AT89C51RC
Description
Manufacturer
Atmel Corporation
Datasheet

Specifications of AT89C51RC

Flash (kbytes)
32 Kbytes
Max. Operating Frequency
24 MHz
Cpu
8051-12C
Max I/o Pins
32
Uart
1
Sram (kbytes)
0.5
Operating Voltage (vcc)
4.0 to 6.0
Timers
3
Watchdog
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT89C51RC-24AC
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51RC-24AI
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51RC-24AU
Manufacturer:
ATMEL
Quantity:
5 000
Part Number:
AT89C51RC-24AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51RC-24JC
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51RC-24JI
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51RC-24JU
Manufacturer:
ATMEL
Quantity:
34 960
Part Number:
AT89C51RC-24JU
Manufacturer:
ATMEL
Quantity:
5 000
Part Number:
AT89C51RC-24JU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT89C51RC-24PC
Manufacturer:
ATM
Quantity:
2 900
Part Number:
AT89C51RC-24PI
Manufacturer:
SANYO
Quantity:
12
Part Number:
AT89C51RC-24PI
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
22
AT89C51RC
Chip Erase Sequence: Before the AT89C51RC can be reprogrammed, a Chip Erase operation
needs to be performed. To erase the contents of the AT89C51RC, follow this sequence:
Data Polling: The AT89C51RC features Data Polling to indicate the end of a write cycle. During
a write cycle, an attempted read of the last byte written will result in the complement of the writ-
ten data on P0.7. Once the write cycle has been completed, true data is valid on all outputs, and
the next cycle may begin. Data Polling may begin any time after a write cycle has been initiated.
Ready/Busy: The progress of byte programming can also be monitored by the RDY/BSY output
signal. P3.0 is pulled low after ALE goes high during programming to indicate BUSY. P3.0 is
pulled high again when programming is done to indicate READY.
Program Verify: If lock bits LB1 and LB2 have not been programmed, the programmed code
data can be read back via the address and data lines for verification. The status of the individual
lock bits can be verified directly by reading them back.
Reading the Signature Bytes: The signature bytes are read by the same procedure as a nor-
mal verification of locations 000H, 100H, and 200H, except that P3.6 and P3.7 must be pulled to
a logic low. The values returned are as follows:
1. Raise V
2. Pulse ALE/PROG once (duration of 200 ns - 500 ns) and wait for 150 ms.
3. Power V
4. Pulse ALE/PROG once (duration of 200 ns - 500 ns) and wait for 150 ms.
5. Power V
(000H) = 1EH indicates manufactured by Atmel
(100H) = 51H
(200H) = 07H indicates 89C51RC
CC
CC
CC
to 6.5V.
down and up to 6.5V.
down and up.
1920D–MICRO–6/08

Related parts for AT89C51RC