Specifications of SAM7S128

Flash (kbytes)
128 Kbytes
Pin Count
64
Max. Operating Frequency
55 MHz
Cpu
ARM7TDMI
Hardware Qtouch Acquisition
No
Max I/o Pins
32
Ext Interrupts
32
Usb Transceiver
1
Usb Speed
Full Speed
Usb Interface
Device
Spi
1
Twi (i2c)
1
Uart
3
Ssc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
32
Self Program Memory
NO
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
3.0 to 3.6
Fpu
No
Mpu / Mmu
no / no
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
40.6.7
40.6.7.1
40.6.7.2
40.6.7.3
40.6.7.4
6175L–ATARM–28-Jul-11
Pulse Width Modulation Controller (PWM)
PWM: Counter Start Value
PWM: Constraints on Duty Cycle Value
PWM: Update when PWM_CCNTx = 0 or 1
PWM: Update when PWM_CPRDx = 0
Note:
When changing CSS in the PMC_MCKR to switch from
Ensure that the processor is executing out of SRAM and ensure no transition occurs on PA1,
either as an input or output, starting from writing to the PMC_MCKR register until MCKRDY = 1.
If the Channel Counter Register value is 0 or 1, the Channel Period Register or Channel Duty
Cycle Register is directly modified when writing the Channel Update Register.
Check the Channel Counter Register before writing the update register.
When Channel Period Register equals 0, the period update is not operational.
Do not write 0 in the period register.
In left aligned mode, the first start value of the counter is 0. For the other periods, the counter
starts at 1.
None.
Setting Channel Duty Cycle Register (PWM_CDTYx) at 0 in center aligned mode or at 0 or 1 in
left aligned mode may change the polarity of the signal.
Do not set PWM_CDTYx at 0 in center aligned mode.
Do not set PWM_CDTYx at 0 or 1 in left aligned mode.
1. Switching from:
2. Program code is being executed out of flash, or a transition is occurring on PA1, either
And
Problem Fix/Workaround
Problem Fix/Workaround
Problem Fix/Workaround
Problem Fix/Workaround
Problem Fix/Workaround
– PLL Clock to Slow Clock or
– PLL Clock to Main Clock or
– Main Clock to PLL Clock or
– Main Clock to Slow Clock
as an input or output.
– PLL Clock to Slow Clock or
– PLL Clock to Main Clock or
– Main Clock to PLL Clock or
– Main Clock to Slow Clock
This issue does not occur when transitioning from slow clock to main clock or from slow clock to
PLL clock.
SAM7S Series