10. Errata
10.1
10.1.1
10.1.2
10.1.3
10.1.4
9166CS–AVR-08/11
rev E
AST
aWire
Power Manager
SCIF
1
1
1
1
2
AST wake signal is released one AST clock cycle after the BUSY bit is cleared
After writing to the Status Clear Register (SCR) the wake signal is released one AST clock
cycle after the BUSY bit in the Status Register (SR.BUSY) is cleared. If entering sleep mode
directly after the BUSY bit is cleared the part will wake up immediately.
Fix/Workaround
Read the Wake Enable Register (WER) and write this value back to the same register. Wait
for BUSY to clear before entering sleep mode.
aWire MEMORY_SPEED_REQUEST command does not return correct CV
The aWire MEMORY_SPEED_REQUEST command does not return a CV corresponding to
the formula in the aWire Debug Interface chapter.
Fix/Workaround
I s s u e a d u m m y r e a d t o a d d r e s s 0 x 1 0 0 0 0 0 0 0 0 b e f o r e i s s u i n g t h e
MEMORY_SPEED_REQUEST command and use this formula instead:
TWIS may not wake the device from sleep mode
If the CPU is put to a sleep mode (except Idle and Frozen) directly after a TWI Start condi-
tion, the CPU may not wake upon a TWIS address match. The request is NACKed.
Fix/Workaround
When using the TWI address match to wake the device from sleep, do not switch to sleep
modes deeper than Frozen. Another solution is to enable asynchronous EIC wake on the
TWIS clock (TWCK) or TWIS data (TWD) pins, in order to wake the system up on bus
events.
PLLCOUNT value larger than zero can cause PLLEN glitch
Initializing the PLLCOUNT with a value greater than zero creates a glitch on the PLLEN sig-
nal during asynchronous wake up.
Fix/Workaround
The lock-masking mechanism for the PLL should not be used.
The PLLCOUNT field of the PLL Control Register should always be written to zero.
PLL lock might not clear after disable
Under certain circumstances, the lock signal from the Phase Locked Loop (PLL) oscillator
may not go back to zero after the PLL oscillator has been disabled. This can cause the prop-
agation of clock signals with the wrong frequency to parts of the system that use the PLL
clock.