2-1658017-5 TE Connectivity, 2-1658017-5 Datasheet
2-1658017-5
Specifications of 2-1658017-5
Related parts for 2-1658017-5
2-1658017-5 Summary of contents
Page 1
... These two-piece connector designs accommodate a variety of printed circuit board thicknesses. Receptacle assemblies are loaded with .006 thick MICTOR SB contacts which mate with blade contacts in the plug assemblies. MICTOR SB connectors are available in three contact centerline versions and 40, 80, 120, 160 and 200 positions. 1.2. Qualification When tests are performed on the subject product line, procedures specified in Figure 1 shall be used ...
Page 2
... EIA-638. Subject contacts to solderability. EIA-364-28, Test Condition V. Subject specimens to 7.56 G's rms between 50 to 2000 Hz. One hour in each of 3 mutually perpendicular planes. EIA-364-27, Method A. Subject specimens to 50 G's half- sine shock pulses of 11 milliseconds duration. Three ...
Page 3
... NOTE tests as specified in the Product Qualification and Requalification Test Sequence shown in Figure 2. The use of alternate gold plating thickness parts (gold flash or 30 microinch gold) can be expected to have the same electrical, mechanical and dielectric performance characteristics. Decision to use such parts should depend on customer’s need for alternate durability or environmental performance characteristics ...
Page 4
... Specimen Selection Specimens shall be prepared in accordance with applicable Instruction Sheets and shall be selected at random from current production. Test groups 1 and 2 each shall consist of 3 mated pairs (plug and receptacle) of vertical assemblies. Test group 3 shall consist of 5 unmounted, mated pairs (plug and receptacle) of vertical assemblies with housings fully populated with signal contacts and bus bars ...
Page 5
... Quality Conformance Inspection The applicable quality inspection plan shall specify the sampling acceptable quality level to be used. Dimensional and functional requirements shall be in accordance with the applicable product drawing and this specification. Low Level Contact Resistance Measurement Points Rev B Figure 3 108-2139 ...