Page 1
... AW G stranded conductors. The m axim um conductor insulation diam eter is 1. [0.045 in]. 1.2. Qualification W hen tests are perform ed on the subject product line, procedures specified in Figure 1 shall be used. All inspections shall be perform ed using the applicable inspection plan and product drawing. 1.3. Qualification Test Results Successful qualification testing on the subject product line was com pleted in Feb00 ...
Page 2
... Perform ance and Test Description Product is designed to m eet the electrical, m echanical and environm ental perform ance requirem ents specified in Figure 1. Unless otherwise specified, all tests shall be perform bient environm ental conditions per Test Specification 109-1. 3.5. Test Requirem ents and Procedures Sum m ary Test Description Exam ination of product ...
Page 3
... TE Spec 109-22 (Rev C). Subject m ated specim ens to 100 cycles between -40 and 70°C. TE Spec 109-23-4 (Rev J), Condition C. Subject m ated specim ens to 21 cycles between 25 and 65°C at 95% RH with -10 C cold shock. TE Spec 109-43 (Rev E). Subject m ated specim ens to tem perature life at 70°C for 500 hours ...
Page 4
... See paragraph 4.1.A. NOTE (b) Numbers indicate sequence in which tests are performed. (c) Perform 100 cycles on jack interface before thermal shock, 33 cycles after 50 cycles of thermal shock, 33 cycles after 7 days of humidity-temperature cycling, and 34 cycles after 21 days of humidity-temperature cycling. (d) Precondition jack interface with 10 cycles durability. Rev C ...
Page 5
... Acceptance Acceptance is based on verification that the product m eets the requirem ents of Figure 1. Failures attributed to equipm ent, test setup or operator deficiencies shall not disqualify the product. If product failure occurs, corrective action shall be taken and specim ens resubm itted for qualification. Testing to confirm corrective action is required before resubm ittal ...
Page 6