2-178139-5 TE Connectivity, 2-178139-5 Datasheet
2-178139-5
Specifications of 2-178139-5
Related parts for 2-178139-5
2-178139-5 Summary of contents
Page 1
... TE Specifications : A. 114-5148 : Application Specification B. 501-5013, 501-78324 : Qualification Test Report 2.2 Commercial Standards and Specifications : A. MIL-STD-202 : Test Methods for Electronic and B. EIA-364 : Electrical Connector / Socket Test Procedures Including Enveronmental Classifications 3. Requirements: 3.1 Design and Construction : Product shall be of the design, construction and physical dimensions specified on the applicable product drawing ...
Page 2
... UL 94V-0 C.Accessories and Hardware(Retention leg): (1) Material : Copper alloy (2) Finish 3.3 Ratings : A.Voltage Rating : B.Current Rating : Refer to Fig.2 and 5 for C. Temperature Rating :-55℃ ~ +105℃ 電 線 サ イ ズ #18 #20 #22 12 ...
Page 3
... Visual inspection drawing and TE Specification No physical damage 114- 5148 電 気 的 性 能 Electrical Requirements 5 mΩ 以下(初期) ハウジングに組み込まれ嵌合したコンタ ...
Page 4
... Requirements 機 械 的 性 能 Mechanical Requirements 49 N 以上 コンタクト引抜力を軸方向に加えること。 (圧着タイプのみ) 操 ...
Page 5
... Measure the force required to insert Per 1 contact contact into housing. 振動中1μs. をこえる不連続導 振動周波数 : 10~500Hz / 15 min 通を生じないこと。 加速度 振動方向 ...
Page 6
... EIA364-52 MIL-STD-202 試験法208 Wet Solder Coverage : Solder Temperature : ...
Page 7
... Termination Resistance Mated/Unmated connector (Low Level) -55° min.,+85° min. Making this a cycle, repeat 25 cycles. EIA364-32 MIL-STD-202 Method 107 Condition A-1 試験後、絶縁抵抗、耐電圧及び 嵌合したコネクタ25~65°C, 総 ...
Page 8
... EIA364-31B Test Condition A MIL-STD-202 Method 103 Condition B 試験後、総合抵抗(ローレベル) 嵌合したコネクタ の条件に合致すること。 ...
Page 9
... Rev. J5 Product Specification 製品規格 Fig.4 Fig.5 108-5349 ...
Page 10
... Temperature Life 塩水噴霧 Salt Spray (a) 欄内の数字は試験の順序を示す。/Numbers indicate sequence in which the tests are performed. Rev. J5 Product Specification 製品規格 ...
Page 11
... Pressure 4.2 製品再認定試験 もし製品に、形状、組合せや嵌合、又は機能に ...
Page 12
... Testing to confirm corrective action is required before resubmittal. 4.4 Quality Conformance Inspection: The applicable quality inspection plan will specify the sampling acceptable quality level to be used. Dimensional and functional requirements shall be in accordance with the applicable product drawing and this specification. 108-5349 ...