5-868403-1 TE Connectivity, 5-868403-1 Datasheet - Page 3

5-868403-1

Manufacturer Part Number
5-868403-1
Description
Manufacturer
TE Connectivity
Datasheet

Specifications of 5-868403-1

Product Type
Lead Assembly
Mount Angle
Straight
Wire Size (mm² [awg])
16
Operating Voltage (kvdc)
20
Shielded
Yes
Lead Assembly Type
Double Ended without Caps
Assembly Length (mm [in])
190.50 [7.500]
Positive Stop Ferrule
Without
Ground Lead Wire Insulation
FEP
Ground Wire Size (awg)
22
Wire Insulation
Silicone
Preloaded
Yes
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Rev O2
Vibration, sinusoidal.
Mechanical shock.
Durability.
Contact engaging force.
Contact separating force.
Therm al shock.
Hum idity, steady state.
Tem perature life.
Test Description
No discontinuities of 10
m icroseconds or longer duration.
See Note.
No discontinuities of 1 m icrosecond
or longer duration.
See Note.
See Note.
20 ounces m axim um .
3 ounces m inim um .
See Note.
See Note.
See Note.
ENVIRONMENTAL
MECHANICAL
Figure 1 (cont)
Requirem ent
EIA-364-28, Test Condition I.
Subject m ated specim ens to 10-55-
10 Hz traversed in 1 m inute with 1.5
m m [.06 in] m axim um total
excursion. 2 hours in each of 3
m utually perpendicular planes.
EIA-364-27, Method H.
Subject m ated specim ens to 30 G's
half-sine shock pulses of 11
m illiseconds duration. 3 shocks in
each direction applied along 3
m utually perpendicular planes, 18
total shocks.
EIA-364-9.
Mate and unm ate gold plated
specim ens for 500 cycles and tin
plated specim ens for 50 cycles at a
m axim um rate of 500 cycles per
hour.
AMP Spec 109-35.
Measure force necessary to
engage using gage 2 to a depth of
.19 inch for 1/2I and 1/2LI and .25
inch for 1I, 1LI, 2I, 3I and 4I.
See Figure 4.
AMP Spec 109-35.
Size 3 tim es using gage 2. Then
insert gage 1 to depth of .19 inch
for 1/2I and 1/2LI and .25 inch for
1I, 1LI, 2I, 3I and 4I and m easure
force necessary to separate.
See Figure 4.
EIA-364-32.
Subject specim ens to 5 cycles
between -55 and 125 C.
EIA-364-31, Method II, Condition A.
Subject specim ens to 40 C and 90
to 95% RH for 96 hours.
EIA-364-17, Method A, Test
Condition 5, Test Tim e Condition A.
Subject m ated specim ens to 125 C
for 96 hours.
Procedure
108-36033
3 of 6

Related parts for 5-868403-1