322-HCS5P2-400 TE Connectivity, 322-HCS5P2-400 Datasheet - Page 3

322-HCS5P2-400

Manufacturer Part Number
322-HCS5P2-400
Description
Manufacturer
TE Connectivity
Datasheet

Specifications of 322-HCS5P2-400

Socket Style
Standard
Profile
Zero
Frame Style
Film Carrier
Leg Style
Straight
Proprietary Name
HOLTITE
Contact Resistance (m?)
10
Contact Rating
3A
Termination Post Length (mm [in])
3.18 [0.125]
Height Above Pc Board (mm [in])
0.00 [0.000]
Centerline (mm [in])
2.54 [0.100]
Row-to-row Spacing (mm [in])
10.16 [0.400]
Number Of Positions
1
Mount Style
Vertical
Contact Termination Type
Through Hole
Contact Base Material
Beryllium Copper
Contact Plating, Mating Area, Material
Gold
Contact Style
Screw Machine
Mating Contact Type
Four-Fingered
Number Of Patterns Per Reel
1
Carrier Strip Material
Mylar
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Temperature Range (°c)
-55 – +125
Packaging Method
Reel
Packaging Quantity
5,000
Rev B
Insertion force.
Withdrawal force.
Contact retention.
Thermal shock.
Humidity-temperature cycling.
Salt spray.
Temperature cycling.
NOTE
Test Description
Shall meet visual requirements, show no physical damage, and meet requirements of additional
tests as specified in the Product Qualification and Requalification Test Sequence shown in Figure
2.
330 grams maximum.
16 grams minimum.
2,267 grams minimum.
See Note.
See Note.
See Note.
See Note.
ENVIRONMENTAL
Figure 1 (end)
Requirement
EIA-364-13.
Measure the force necessary to
insert a .020 inch diameter polished
steel test pin at a maximum rate of
12.7 mm [.5 in] per minute.
EIA-364-13.
Measure force necessary to
withdraw a .016 inch diameter
polished steel test pin at a
maximum rate of 12.7 mm [.5 in]
per minute.
EIA-364-13.
Measure force necessary to push a
contact out of an .039 inch diameter
plated through hole.
EIA-364-32, Test Condition IV.
Subject specimens to 5 cycles
between -65 and 150° C.
EIA-364-31, Method III.
Subject specimens to 10 cycles (10
days) between 25 and 65° C at 80 to
100% RH.
EIA-364-26, Test Condition B.
Subject specimens to a 5% salt fog
mist for 48 hours.
EIA-364-32, Test Condition VII.
Except: Subject specimens to 100
cycles between -40 and 120° C,
dwell time and transition time shall
be 30 minutes (120 minute cycle).
Procedure
108-1979
3 of 5

Related parts for 322-HCS5P2-400