520982-2 TE Connectivity, 520982-2 Datasheet - Page 5

520982-2

Manufacturer Part Number
520982-2
Description
Manufacturer
TE Connectivity
Datasheets

Specifications of 520982-2

Proprietary Name
Ultra-Pod
Receptacle Style
Straight
Mating Area Interface Dimensions (mm [in])
4.75 x 0.81 [.187 x .032]
Insulation Diameter (mm [in])
2.29-3.30 [.090-.130]
Insertion Force
Low
Finish
Tin
Insulation Support
Insulation Support
Ul Listed
File No. E66717
Color
Natural
Fully Insulated
Yes
Wire Range (mm [awg])
0.50-1.40² [20-16]
Ul Flammability Rating
UL 94V-2
Housing Material
Nylon
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Csa Certified
Yes
Packaging Method
Strip

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
520982-2
Manufacturer:
TE
Quantity:
20 000
|
|
|
|
|
4.
4.1.
4.2.
4.3.
4.4.
4.5.
Rev D
QUALITY ASSURANCE PROVISIONS
Qualification Testing
A.
B.
Requalification Testing
If changes significantly affecting form , fit, or function are m ade to the product or to the m anufacturing
process, product assurance shall coordinate requalification testing, consisting of all or part of the
original testing sequence as determ ined by developm ent/product, quality, and reliability engineering.
Acceptance
Acceptance is based on verification that the product m eets the requirem ents of Figure 1. Failures
attributed to equipm ent, test setup, or operator deficiencies shall not disqualify the product. W hen
product failure occurs, corrective action shall be taken and sam ples resubm itted for qualification.
Testing to confirm corrective action is required before resubm ittal.
Quality Conform ance Inspection
The applicable quality inspection plan will specify the sam pling acceptable quality level to be used.
Dim ensional and functional requirem ents shall be in accordance with the applicable product drawing
and this specification.
This product has been listed by Underwriters' Laboratories Inc., Electrical File Num ber E-66717 and
certified by Canadian Standards Association Certification Num ber LR-7189.
Certification
Sam ple Selection
Term inals and tabs shall be prepared in accordance with applicable Instruction Sheets. They shall
be selected at random from current production. Test groups 3, 4, 5, 6, and 7 shall consist of 20
sam ples of each term inal type per group. Test groups 1 and 2 shall consist of 20 sam ples of each
wire size and term inal type per group. Test group 8 shall consist of 20 sam ples of each term inal
type per group on the m axim um wire size for the intended range of wires. All sam ples to be
term inated shall be crim ped to appropriate tin plated test conductors. Test groups 9 and 10 shall
each consist of 6 specim ens of each term inal type per group. All specim ens shall be crim ped to
the appropriate tin plated test conductors.
Test Sequence
Qualification inspection shall be verified by testing sam ples as specified in Figure 2.
108-1285