The DS2422 temperature/data logger combines the core functions of a fully featured data logger in a single chip
Manufacturer
Maxim
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS2422S
Manufacturer:
DALLAS
Quantity:
20 000
MISSION CONTROL
The DS2422 is set up for its operation by writing appropriate data to its special function registers, which are located
in the two register pages. The settings in the Mission Control Register determine whether temperature and/or
external data is logged, which format (8 or 16 bits) is to be used and whether old data may be overwritten by new
data, once the datalog memory is full. An additional control bit can be set to tell the DS2422 to wait with logging
data until a temperature alarm is encountered.
Mission Control Register Bitmap
During a mission, there is only read access to this register. Bits 6 and 7 have no function. They always read 1 and
cannot be written to 0.
Register Details
ETL: Enable Temperature
Logging
EDL: Enable Data Logging
TLFS: Temperature
Logging Format Selection
DLFS: Data Logging
Format Selection
RO: Rollover Control
SUTA: Start Mission upon
Temperature Alarm
ADDR
0213h
BIT DESCRIPTION
b7
1
b6
1
SUTA
BIT(S)
b5
b0
b1
b2
b3
b4
b5
To set up the device for a temperature-logging mission, this bit must be
To set up the device for a data-logging mission (recording data from
serial data interface), this bit must be set to logic 1. To successfully
start a mission, ETL or EDL must be 1. If only data logging is enabled
(no temperature data), the recorded data values will be stored starting
at address 1000h. If both, temperature and data logging are enabled,
the recorded data values will begin at address 2000h (TLFS = DLFS)
or 1A00h (TLFS = 0; DLFS = 1) or 2400h (TLFS = 1; DLFS = 0).
This bit specifies the format used to store temperature readings in the
This bit specifies the format used to store data readings from the serial
This bit controls whether, during a mission, the datalog memory is
This bit specifies whether a mission begins immediately (includes
set to logic 1. To successfully start a mission, ETL or EDL must be 1. If
temperature logging is enabled, the recorded temperature values will
always be stored starting at address 1000h.
datalog memory. If this bit is 0, the data will be stored in 8-bit format. If
this bit is 1, the 16-bit format will be used (higher resolution). With 16-
bit format, the most-significant byte is stored at the lower address.
data interface in the datalog memory. If this bit is 0, the data will be
stored in 8-bit format. If this bit is 1, the 16-bit format will be used
(higher resolution). With 16-bit format, the most-significant byte is
stored at the lower address.
overwritten with new data or whether data logging is stopped once the
datalog memory is full. Setting this bit to 1 enables the rollover and
data logging continues at the beginning, overwriting previously
collected data. If this bit is 0, the logging and conversions will stop
once the datalog memory is full. However, the RTC will continue to run
and the MIP bit will remain set until the Stop Mission command is
performed.
delayed start) or if a temperature alarm will be required to start the
mission. If this bit is 1, the device will perform an 8-bit temperature
conversion at the selected sample rate and begin with data logging
only if an alarming temperature (high alarm or low alarm) was found.
The first logged temperature is when the alarm occurred. However, the
mission sample counter does not increment. This functionality is
guaranteed by design and not production tested.
RO
b4
DLFS
17 of 49
b3
TLFS
b2