Page 1
... MAX16913A also feature a short-to-battery detection every time the internal switch turns on. These devices provide an active-high control input to put the devices in low-power shutdown mode. The MAX16913/MAX16913A are available in the 16-pin QSOP package and operate over the -40°C to +105°C temperature range. Remote LNA Phantom Power ...
Page 2
... Measured between SENS and OUT while V D sourcing 100mA T Temperature rising SHDN T HYST V REF Z REF R = 1Ω 0.66V for the SENSE OLT I OL MAX16913 only) V (MAX16913A only) OLR 1Ω SC SENSE V At current limit 14V LIM rising OVLO IN t BLANK t RETRY ) (Note 1) ......25°C (Note 1) .....55° ...
Page 3
ELECTRICAL CHARACTERISTICS (continued +9V to +18V MIN PARAMETER SYMBOL LOGIC LEVELS SC, OL Output-Voltage Low SC, OL Output-Leakage Current SHDN Input Low Voltage SHDN Input High Voltage TIMING ...
Page 4
Remote Antenna Current-Sense Amplifier and Switches (V = 14V 1Ω +25°C, unless otherwise noted.) IN SENSE A TOTAL CURRENT MEASUREMENT ERROR vs SENSE ...
Page 5
... Nominal Reference Output. Use a resistive divider between REF, OLT, and ground to set the open-load 12 REF current threshold (MAX16913A). The output impedance of this voltage regulator is 5kΩ. Current-Monitor Voltage Output. AOUT can be used to measure the load current by means of an external 13 AOUT ADC. The output impedance is 5kΩ ...
Page 6
... MAX16913A features an adjustable open-load threshold. For the MAX16913, when (V 20mV (typ), the device signals open load. For the MAX16913A, using a resistive divider between REF, the open-load threshold adjustment pin (OLT), and GND sets the open-load threshold (see the Open- Load Threshold Selection section). ...
Page 7
... Short-to-Battery Detection It may happen that OUT is shorted to the battery due to a fault in the system. The MAX16913/MAX16913A detect this failure by comparing the OUT voltage and the IN voltage before the switch turns on. Every time the switch turns on, such as at the end of the retry time, or once the thermal shutdown condition disappears, the short-to-battery detection is performed ...
Page 8
... V the switch and the internal charge pump. The MAX16913/MAX16913A feature a +3V bandgap reference output, stable over supply voltage and tem- perature. For the MAX16913A, the reference output is DEVICE STATUS connected to the resistive divider which sets the open- OUT Short-to-Battery load threshold ...
Page 9
... R , avoid parasitic trace SENSE resistance from causing errors in the sense voltage. Open-Load Threshold Selection For the MAX16913A, a resistive divider between REF, OLT, and GND sets the open-load threshold. See Figure 3. Use the following formula to set the desired open-load threshold: Ω ...
Page 10
... TOP VIEW + GND SENS 3 MAX16913 SENS 4 MAX16913A OUT 5 OUT 6 SHDN 7 GND 8 QSOP Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied ...